Danfoss VLT AutomationDrive FC 301 Programming Manual page 272

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

Parameter Lists
5.3.13 13-** Smart Logic
Par-
Parameter description
ameter #
13-0* SLC Settings
13-00
SL Controller Mode
13-01
Start Event
13-02
Stop Event
13-03
Reset SLC
13-1* Comparators
5
5
13-10
Comparator Operand
13-11
Comparator Operator
13-12
Comparator Value
13-1* RS Flip Flops
13-15
RS-FF Operand S
13-16
RS-FF Operand R
13-2* Timers
13-20
SL Controller Timer
13-4* Logic Rules
13-40
Logic Rule Boolean 1
13-41
Logic Rule Operator 1
13-42
Logic Rule Boolean 2
13-43
Logic Rule Operator 2
13-44
Logic Rule Boolean 3
13-5* States
13-51
SL Controller Event
13-52
SL Controller Action
5.3.14 14-** Special Functions
Par-
Parameter description
ameter #
14-0* Inverter Switching
14-00
Switching Pattern
14-01
Switching Frequency
14-03
Overmodulation
14-04
PWM Random
14-06
Dead Time Compensation
14-1* Mains On/Off
14-10
Mains Failure
14-11
Mains Voltage at Mains Fault
14-12
Function at Mains Imbalance
14-14
Kin. Backup Time Out
14-15
Kin. Backup Trip Recovery Level
14-16
Kin. Backup Gain
14-2* Trip Reset
14-20
Reset Mode
14-21
Automatic Restart Time
14-22
Operation Mode
14-23
Typecode Setting
14-24
Trip Delay at Current Limit
14-25
Trip Delay at Torque Limit
270
®
VLT
AutomationDrive FC 301/302
Default value
ExpressionLimit
ExpressionLimit
ExpressionLimit
[0] Do not reset SLC
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
Default value
[1] SFAVM
ExpressionLimit
[1] On
[0] Off
[1] On
[0] No function
ExpressionLimit
[0] Trip
60 s
ExpressionLimit
100 %
[0] Manual reset
ExpressionLimit
[0] Normal operation
ExpressionLimit
60 s
60 s
Danfoss A/S © 01/2018 All rights reserved.
4 set-up
FC 302
Change
only
during
operation
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
All set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
1 set-up
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
4 set-up
FC 302
Change
only
during
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
x
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
2 set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
Conversi
Type
on index
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-3
Int32
-
Uint8
-
Uint8
-3
TimD
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
Conversi
Type
on index
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint16
-
Uint8
0
Uint8
-3
Uint32
0
Uint32
-
Uint8
0
Uint16
-
Uint8
-
Uint8
0
Uint8
0
Uint8
MG33MO02