Danfoss VLT AutomationDrive FC 301 Programming Manual page 204

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

Parameter Descriptions
18-38 Temp. Input X48/7
Range:
0
[-500 -
*
500]
3
3
18-39 Temp. Input X48/10
Range:
0
[-500 -
*
500]
3.18.2 18-4* PGIO Data Readouts
Parameters for configuring the readout of VLT
Programmable I/O MCB 115.
18-43 Analog Out X49/7
Range:
0
[0 - 30] Shows the actual value at output of terminal X49/7
*
18-44 Analog Out X49/9
Range:
0
[0 - 30] Shows the actual value at output of terminal X49/9
*
18-45 Analog Out X49/11
Range:
0
[0 - 30] Shows the actual value at output of terminal
*
3.18.3 18-5* Active Alarms/Warnings
The parameters in this group show the numbers of
currently active alarms or warnings.
18-55 Active Alarm Numbers
Range:
0
[0 - 65535] This parameter contains an array of up to 20
*
18-56 Active Warning Numbers
Range:
0
[0 - 65535] This parameter contains an array of up to 20
*
202
Function:
View the actual temperature measured at input
X48/7. The temperature unit is based on the
selection in parameter 35-02 Term. X48/7
Temperature Unit.
Function:
View the actual temperature measured at input
X48/10. The temperature unit is based on the
selection in parameter 35-04 Term. X48/10
Temperature Unit.
Function:
in V or mA. The value reflects the selection in
parameter 36-40 Terminal X49/7 Analogue Output.
Function:
in V or mA. The value reflects the selection in
parameter 36-50 Terminal X49/9 Analogue Output.
Function:
X49/11 in V or mA. The value reflects the selection
in parameter 36-60 Terminal X49/11 Analogue
Output.
Function:
alarms that are currently active. The value 0
means no alarm.
Function:
warnings that are currently active. The value 0
means no warning.
Danfoss A/S © 01/2018 All rights reserved.
®
VLT
AutomationDrive FC 301/302
18-60 Digital Input 2
Range:
0
[0 - 65535] Shows the signal states from the active digital
*
18-70 Mains Voltage
Range:
0 V
*
18-71 Mains Frequency
Range:
0 Hz
*
18-72 Mains Imbalance
®
Range:
0 %
*
18-75 Rectifier DC Volt.
Range:
0 V
[0 - 10000 V] Shows the DC voltage measured on the
*
18-90 Process PID Error
Range:
0 %
*
18-91 Process PID Output
Range:
0 %
*
18-92 Process PID Clamped Output
Range:
0 %
*
18-93 Process PID Gain Scaled Output
Range:
0 %
*
200 %]
Function:
inputs.
0 = No signal.
1 = Connected signal.
Function:
[0 - 1000 V]
Shows the mains line-to-line voltage.
Function:
[-100 - 100 Hz]
Shows the mains frequency.
Function:
[0 - 100 %] Shows the maximum imbalance for the 3
mains line-to-line measurements.
Function:
rectifier module.
Function:
[-200 - 200 %] Give the present error value used by the
process PID controller.
Function:
[-200 - 200 %] Give the present raw output value from
the process PID controller.
Function:
[-200 - 200 %] Give the present output value from the
process PID controller after the clamp
limits have been observed.
Function:
[-200 -
Give the present output value from the
process PID controller after the clamp
limits have been observed, and the
resulting value has been gain scaled.
MG33MO02