Danfoss VLT AutomationDrive FC 301 Programming Manual page 233

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

Parameter Lists
1-97
Thermistor Threshold level
1-98
ATEX ETR interpol. points freq.
1-99
ATEX ETR interpol points current
5.2.3 2-** Brakes
Para
Parameter description
mete
r
num
ber
2-0* DC-Brake
2-00
DC Hold Current
2-01
DC Brake Current
2-02
DC Braking Time
2-03
DC Brake Cut In Speed [RPM]
2-04
DC Brake Cut In Speed [Hz]
2-05
Maximum Reference
2-06
Parking Current
2-07
Parking Time
2-1* Brake Energy Funct.
2-10
Brake Function
2-11
Brake Resistor (ohm)
2-12
Brake Power Limit (kW)
2-13
Brake Power Monitoring
2-15
Brake Check
2-16
AC brake Max. Current
2-17
Over-voltage Control
2-18
Brake Check Condition
2-19
Over-voltage Gain
2-2* Mechanical Brake
2-20
Release Brake Current
2-21
Activate Brake Speed [RPM]
2-22
Activate Brake Speed [Hz]
2-23
Activate Brake Delay
2-24
Stop Delay
2-25
Brake Release Time
2-26
Torque Ref
2-27
Torque Ramp Up Time
2-28
Gain Boost Factor
2-29
Torque Ramp Down Time
2-3* Adv. Mech Brake
2-30
Position P Start Proportional Gain
2-31
Speed PID Start Proportional Gain
2-32
Speed PID Start Integral Time
2-33
Speed PID Start Lowpass Filter Time
5.2.4 3-** Reference / Ramps
Para
Parameter description
mete
r
num
ber
MG33MO02
Programming Guide
80 °C
1 set-up
ExpressionLimit
1 set-up
ExpressionLimit
2 set-ups
Default value
4 set-up
50 %
All set-ups
50 %
All set-ups
10 s
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
MaxReference (P303)
All set-ups
50 %
All set-ups
3 s
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[0] Off
All set-ups
[0] Off
All set-ups
100 %
All set-ups
[0] Disabled
All set-ups
[0] At Power Up
All set-ups
100 %
All set-ups
ImaxVLT (P1637)
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0 s
All set-ups
0 s
All set-ups
0.20 s
All set-ups
0 %
All set-ups
0.2 s
All set-ups
1 N/A
All set-ups
0 s
All set-ups
0.0000 N/A
All set-ups
0.0150 N/A
All set-ups
200.0 ms
All set-ups
10.0 ms
All set-ups
Default value
4 set-up
Danfoss A/S © 01/2018 All rights reserved.
TRUE
100
x
TRUE
-1
x
TRUE
0
FC 302 only
Change
Conversio
during
n index
operation
TRUE
0
TRUE
0
TRUE
-1
TRUE
67
TRUE
-1
TRUE
-3
TRUE
0
TRUE
-1
TRUE
-
TRUE
0
TRUE
0
TRUE
-
TRUE
-
TRUE
-1
TRUE
-
TRUE
-
TRUE
0
TRUE
-2
TRUE
67
TRUE
-1
TRUE
-1
TRUE
-1
TRUE
-2
TRUE
-2
TRUE
-1
TRUE
-2
TRUE
-1
TRUE
-4
TRUE
-4
TRUE
-4
TRUE
-4
FC 302 only
Change
Conversio
during
n index
operation
Int16
Uint16
Uint16
Type
5
5
Uint8
Uint16
Uint16
Uint16
Uint16
Int32
Uint16
Uint16
Uint8
Uint16
Uint32
Uint8
Uint8
Uint32
Uint8
Uint8
Uint16
Uint32
Uint16
Uint16
Uint8
Uint8
Uint16
Int16
Uint8
Uint16
Uint8
Uint32
Uint32
Uint32
Uint16
Type
231

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt automationdrive fc 302

Table of Contents