Danfoss VLT AutomationDrive FC 301 Programming Manual page 153

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

Parameter Descriptions
13-15 RS-FF Operand S
Option:
Function:
NOTICE
[222] Homing Ok
This option is available only
with software version 48.20
and newer.
Homing is completed with the
selected homing function
(parameter 17-80 Homing Function).
NOTICE
[223] On Target
This option is available only
with software version 48.20
and newer.
Positioning is completed and the
on-target signal is sent when the
actual position is within
parameter 3-05 On Reference
Window for the duration of
parameter 3-09 On Target Time and
the actual speed does not exceed
parameter 3-05 On Reference
Window.
NOTICE
[224] Position Error
This option is available only
with software version 48.20
and newer.
The position error exceeds the
value in parameter 4-71 Maximum
Position Error for the time set in
parameter 4-72 Position Error
Timeout.
NOTICE
[225] Position Limit
This option is available only
with software version 48.20
and newer.
The position is outside the limits
set in parameter 3-06 Minimum
Position and
parameter 3-07 Maximum Position.
NOTICE
[226] Touch on Target
This option is available only
with software version 48.20
and newer.
Target position is reached in touch
probe position mode.
MG33MO02
Programming Guide
13-15 RS-FF Operand S
Option:
[227] Touch Activated
13-16 RS-FF Operand R
Option:
[0]
False
[1]
True
[2]
Running
[3]
In range
[4]
On reference
[5]
Torque limit
[6]
Current Limit
[7]
Out of current range
[8]
Below I low
[9]
Above I high
[10]
Out of speed range
[11]
Below speed low
[12]
Above speed high
[13]
Out of feedb. range
[14]
Below feedb. low
[15]
Above feedb. high
[16]
Thermal warning
[17]
Mains out of range
[18]
Reversing
[19]
Warning
[20]
Alarm (trip)
[21]
Alarm (trip lock)
[22]
Comparator 0
[23]
Comparator 1
[24]
Comparator 2
[25]
Comparator 3
[26]
Logic rule 0
[27]
Logic rule 1
[28]
Logic rule 2
[29]
Logic rule 3
[30]
SL Time-out 0
[31]
SL Time-out 1
[32]
SL Time-out 2
[33]
Digital input DI18
[34]
Digital input DI19
[35]
Digital input DI27
[36]
Digital input DI29
[37]
Digital input DI32
[38]
Digital input DI33
[39]
Start command
[40]
Drive stopped
Danfoss A/S © 01/2018 All rights reserved.
Function:
NOTICE
This option is available only
with software version 48.20
and newer.
Touch probe positioning active. The
frequency converter monitors the
touch probe sensor input.
Function:
151
3
3