Parameter Lists
4-30
Motor Feedback Loss Function
4-31
Motor Feedback Speed Error
4-32
Motor Feedback Loss Timeout
4-34
Tracking Error Function
4-35
Tracking Error
4-36
Tracking Error Timeout
4-37
Tracking Error Ramping
4-38
Tracking Error Ramping Timeout
4-39
Tracking Error After Ramping Timeout
4-4* Speed Monitor
4-43
Motor Speed Monitor Function
5
5
4-44
Motor Speed Monitor Max
4-45
Motor Speed Monitor Timeout
4-5* Adj. Warnings
4-50
Warning Current Low
4-51
Warning Current High
4-52
Warning Speed Low
4-53
Warning Speed High
4-54
Warning Reference Low
4-55
Warning Reference High
4-56
Warning Feedback Low
4-57
Warning Feedback High
4-58
Missing Motor Phase Function
4-6* Speed Bypass
4-60
Bypass Speed From [RPM]
4-61
Bypass Speed From [Hz]
4-62
Bypass Speed To [RPM]
4-63
Bypass Speed To [Hz]
4-7* Position Monitor
4-70
Position Error Function
4-71
Maximum Position Error
4-72
Position Error Timeout
4-73
Position Limit Function
4-74
Start Fwd/Rev Function
4-75
Touch Timout
5.3.6 5-** Digital In/Out
Par-
Parameter description
ameter #
5-0* Digital I/O mode
5-00
Digital I/O Mode
5-01
Terminal 27 Mode
5-02
Terminal 29 Mode
5-1* Digital Inputs
5-10
Terminal 18 Digital Input
5-11
Terminal 19 Digital Input
5-12
Terminal 27 Digital Input
5-13
Terminal 29 Digital Input
5-14
Terminal 32 Digital Input
262
®
VLT
AutomationDrive FC 301/302
[2] Trip
300 RPM
0.05 s
ExpressionLimit
10 RPM
1 s
100 RPM
1 s
5 s
ExpressionLimit
300 RPM
0.1 s
0 A
ImaxVLT (P1637)
0 RPM
ExpressionLimit
-999999.999 N/A
999999.999 N/A
-999999.999 Reference-
FeedbackUnit
999999.999 Reference-
FeedbackUnit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
[0] Disabled
1000 CustomRea-
doutUnit2
0.100 s
[3] Abs. Pos. Mode Stop
[0] Stop
6000.0 s
Default value
[0] PNP
[0] Input
[0] Input
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
Danfoss A/S © 01/2018 All rights reserved.
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
4 set-up
FC 302
Change
only
during
operation
All set-ups
FALSE
All set-ups
TRUE
All set-ups
x
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
x
TRUE
All set-ups
TRUE
-
Uint8
67
Uint16
-2
Uint16
-
Uint8
67
Uint16
-2
Uint16
67
Uint16
-2
Uint16
-2
Uint16
-
Uint8
67
Uint16
-2
Uint16
-2
Uint32
-2
Uint32
67
Uint16
67
Uint16
-3
Int32
-3
Int32
-3
Int32
-3
Int32
-
Uint8
67
Uint16
-1
Uint16
67
Uint16
-1
Uint16
-
Uint8
0
Int32
-3
Uint16
-
Uint8
-
Uint8
-1
Uint16
Conversi
Type
on index
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
MG33MO02