Parameter Lists
5.2.24 36-** Programmable I/O Option
Para
Parameter description
mete
r
num
ber
36-0* I/O Mode
36-03 Terminal X49/7 Mode
36-04 Terminal X49/9 Mode
36-05 Terminal X49/11 Mode
36-4* Output X49/7
36-40 Terminal X49/7 Analogue Output
36-42 Terminal X49/7 Min. Scale
36-43 Terminal X49/7 Max. Scale
36-44 Terminal X49/7 Bus Control
36-45 Terminal X49/7 Timeout Preset
36-5* Output X49/9
36-50 Terminal X49/9 Analogue Output
36-52 Terminal X49/9 Min. Scale
36-53 Terminal X49/9 Max. Scale
36-54 Terminal X49/9 Bus Control
36-55 Terminal X49/9 Timeout Preset
36-6* Output X49/11
36-60 Terminal X49/11 Analogue Output
36-62 Terminal X49/11 Min. Scale
36-63 Terminal X49/11 Max. Scale
36-64 Terminal X49/11 Bus Control
36-65 Terminal X49/11 Timeout Preset
5.2.25 40-** Special Settings
Para
Parameter description
mete
r
num
ber
40-4* Extend. Fault Log
40-40 Fault Log: Ext. Reference
40-41 Fault Log: Frequency
40-42 Fault Log: Current
40-43 Fault Log: Voltage
40-44 Fault Log: DC Link Voltage
40-45 Fault Log: Control Word
40-46 Fault Log: Status Word
40-5* Advanced Control Settings
40-50 Flux Sensorless Model Shift
40-51 Flux Sensorless Corr. Gain
MG33MO02
Programming Guide
Default value
4 set-up
[0] Voltage 0-10V
All set-ups
[0] Voltage 0-10V
All set-ups
[0] Voltage 0-10V
All set-ups
[0] No operation
All set-ups
0 %
All set-ups
100 %
All set-ups
0 %
All set-ups
0 %
1 set-up
[0] No operation
All set-ups
0 %
All set-ups
100 %
All set-ups
0 %
All set-ups
0 %
1 set-up
[0] No operation
All set-ups
0 %
All set-ups
100 %
All set-ups
0 %
All set-ups
0 %
1 set-up
Default value
4 set-up
0 %
All set-ups
0 Hz
All set-ups
0 A
All set-ups
0 V
All set-ups
0 V
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
Danfoss A/S © 01/2018 All rights reserved.
FC 302 only
Change
Conversio
during
n index
operation
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
FC 302 only
Change
Conversio
during
n index
operation
FALSE
-1
FALSE
-1
FALSE
-2
FALSE
-1
FALSE
0
FALSE
0
FALSE
0
FALSE
-
TRUE
-1
Type
Uint8
Uint8
Uint8
5
5
Uint8
Int16
Int16
N2
Uint16
Uint8
Int16
Int16
N2
Uint16
Uint8
Int16
Int16
N2
Uint16
Type
Int16
Uint16
Int32
Uint16
Uint16
V2
V2
Uint8
Uint32
255