Parameter Descriptions
16-71 Relay Output [bin]
Range:
0
[0 - 511 ]
*
3
3
16-72 Counter A
Range:
0
[-2147483648
N/A
- 2147483647
N/A]
*
16-73 Counter B
Range:
0
[-2147483648
N/A
- 2147483647
N/A]
*
16-74 Prec. Stop Counter
Range:
0 N/A
[0 - 2147483647
*
N/A]
16-75 Analog In X30/11
Range:
0
[-20 - 20 ] View the actual value at input X30/11 of VLT
*
16-76 Analog In X30/12
Range:
0
[-20 - 20 ] View the actual value at input X30/12 of VLT
*
190
VLT
Function:
View the settings of all relays.
Illustration 3.69 Relay Settings
Function:
View the present value of counter A.
Counters are useful as comparator
operands, see parameter 13-10 Comparator
Operand.
Reset or change the value either via
digital inputs (parameter group 5-1* Digital
Inputs) or by using an SLC action
(parameter 13-52 SL Controller Action).
Function:
View the present value of counter B.
Counters are useful as comparator
operands (parameter 13-10 Comparator
Operand).
Reset or change the value either via digital
inputs (parameter group 5-1* Digital Inputs)
or by using an SLC action
(parameter 13-52 SL Controller Action).
Function:
Returns the actual counter value of
precise counter
(parameter 1-84 Precise Stop Counter
Value).
Function:
General Purpose I/O MCB 101.
Function:
General Purpose I/O MCB 101.
Danfoss A/S © 01/2018 All rights reserved.
®
AutomationDrive FC 301/302
16-77 Analog Out X30/8 [mA]
Range:
0
[0 - 30 ]
*
16-78 Analog Out X45/1 [mA]
Range:
0.000
N/A
30.000 N/A]
*
16-79 Analog Out X45/3 [mA]
Range:
0.000
N/A
30.000 N/A]
*
3.16.6 16-8* Fieldbus & FC Port
Parameters for reporting the bus references and control
words.
16-80 Fieldbus CTW 1
Range:
0
[0 -
*
65535 ]
16-82 Fieldbus REF 1
Range:
0
[-200 - 200 ] View the 2-byte word sent with the control
*
16-83 Fieldbus REF 2
Range:
0 CustomRea-
doutUnit2
*
®
®
Function:
View the actual value at input X30/8 in mA.
Function:
[0.000 -
Shows the actual output value at
terminal X45/1. The value shown
reflects the selection in
parameter 6-70 Terminal X45/1 Output.
Function:
[0.000 -
Shows the actual output value at
terminal X45/3. The value shown
reflects the selection in
parameter 6-80 Terminal X45/3 Output.
Function:
View the 2-byte control word (CTW) received
from the fieldbus master. Interpretation of the
control word depends on the fieldbus option
installed and the control word profile selected in
parameter 8-10 Control Profile.
For more information, refer to the relevant
fieldbus manual.
Function:
word from the fieldbus master to set the
reference value.
For more information, refer to the relevant
fieldbus manual.
Function:
NOTICE
[-2147483647 -
2147483647
This parameter is only
CustomRea-
valid with software
doutUnit2]
version 48.XX.
Shows the 32-bit position
reference sent in PCD 2 and
PCD 3. In parameters related
to PCD 2 and PCD 3, select
[1683] Fieldbus REF 2 for the
MG33MO02