Parameter Descriptions
NOTICE
[224] Position Error
This option is available only with
software version 48.XX.
The position error exceeds the value in
parameter 4-71 Maximum Position Error for
the time set in parameter 4-72 Position
Error Timeout.
NOTICE
[225] Position Limit
This option is available only with
software version 48.XX.
The position is outside the limits set in
parameter 3-06 Minimum Position and
parameter 3-07 Maximum Position.
NOTICE
[226] Touch on
Target
This option is available only with
software version 48.XX.
Target position is reached in touch probe
position mode.
NOTICE
[227] Touch
Activated
This option is available only with
software version 48.XX.
Touch probe positioning active. The
frequency converter monitors the touch
probe sensor input.
[231] In Power Lim.
Mot.
[232] In Power Lim.
Gen.
[233] In Power Limit
5-30 Terminal 27 Digital Output
Option:
Function:
[0]
No operation Functions are described in parameter group
*
5-3* Digital Outputs.
5-31 Terminal 29 Digital Output
Option:
Function:
NOTICE
This parameter is applicable for FC 302
only.
[0]
No operation Functions are described in parameter group
*
5-3* Digital Outputs.
5-32 Term X30/6 Digi Out (MCB 101)
Option:
[0]
No operation
[1]
Control Ready
[2]
Drive ready
MG33MO02
Programming Guide
Function:
This parameter is active when
®
option module VLT
General
Purpose I/O MCB 101 is mounted
in the frequency converter.
Functions are described in
parameter group 5-3* Digital
Outputs.
Danfoss A/S © 01/2018 All rights reserved.
5-32 Term X30/6 Digi Out (MCB 101)
Option:
Function:
[3]
Drive rdy/rem ctrl
[4]
Enable / no warning
[5]
Running
[6]
Running / no warning
[7]
Run in range/no warn
[8]
Run on ref/no warn
[9]
Alarm
[10]
Alarm or warning
[11]
At torque limit
[12]
Out of current range
[13]
Below current, low
[14]
Above current, high
[15]
Out of speed range
[16]
Below speed, low
[17]
Above speed, high
[18]
Out of feedb. range
[19]
Below feedback, low
[20]
Above feedback, high
[21]
Thermal warning
[22]
Ready,no thermal W
[23]
Remote,ready,no TW
[24]
Ready, Voltage OK
[25]
Reverse
[26]
Bus OK
[27]
Torque limit & stop
[28]
Brake, no brake war
[29]
Brake ready, no fault
[30]
Brake fault (IGBT)
[31]
Relay 123
[32]
Mech brake ctrl
[33]
Safe stop active
[38]
Motor feedback error
[39]
Tracking error
[40]
Out of ref range
[41]
Below reference, low
[42]
Above ref, high
[43]
Extended PID Limit
[45]
Bus ctrl.
[46]
Bus ctrl, 1 if timeout
[47]
Bus ctrl, 0 if timeout
[50]
On Reference
[55]
Pulse output
[60]
Comparator 0
[61]
Comparator 1
[62]
Comparator 2
[63]
Comparator 3
[64]
Comparator 4
[65]
Comparator 5
[70]
Logic rule 0
[71]
Logic rule 1
[72]
Logic rule 2
[73]
Logic rule 3
3
3
99