Danfoss VLT AutomationDrive FC 301 Programming Manual page 237

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

Parameter Lists
5-30
Terminal 27 Digital Output
5-31
Terminal 29 Digital Output
5-32
Term X30/6 Digi Out (MCB 101)
5-33
Term X30/7 Digi Out (MCB 101)
5-4* Relays
5-40
Function Relay
5-41
On Delay, Relay
5-42
Off Delay, Relay
5-5* Pulse Input
5-50
Term. 29 Low Frequency
5-51
Term. 29 High Frequency
5-52
Term. 29 Low Ref./Feedb. Value
5-53
Term. 29 High Ref./Feedb. Value
5-54
Pulse Filter Time Constant #29
5-55
Term. 33 Low Frequency
5-56
Term. 33 High Frequency
5-57
Term. 33 Low Ref./Feedb. Value
5-58
Term. 33 High Ref./Feedb. Value
5-59
Pulse Filter Time Constant #33
5-6* Pulse Output
5-60
Terminal 27 Pulse Output Variable
5-62
Pulse Output Max Freq #27
5-63
Terminal 29 Pulse Output Variable
5-65
Pulse Output Max Freq #29
5-66
Terminal X30/6 Pulse Output Variable
5-68
Pulse Output Max Freq #X30/6
5-7* 24V Encoder Input
5-70
Term 32/33 Pulses Per Revolution
5-71
Term 32/33 Encoder Direction
5-8* I/O Options
5-80
AHF Cap Reconnect Delay
5-9* Bus Controlled
5-90
Digital & Relay Bus Control
5-93
Pulse Out #27 Bus Control
5-94
Pulse Out #27 Timeout Preset
5-95
Pulse Out #29 Bus Control
5-96
Pulse Out #29 Timeout Preset
5-97
Pulse Out #X30/6 Bus Control
5-98
Pulse Out #X30/6 Timeout Preset
5.2.7 6-** Analog In/Out
Para
Parameter description
mete
r
num
ber
6-0* Analog I/O Mode
6-00
Live Zero Timeout Time
6-01
Live Zero Timeout Function
6-1* Analog Input 1
6-10
Terminal 53 Low Voltage
6-11
Terminal 53 High Voltage
6-12
Terminal 53 Low Current
MG33MO02
Programming Guide
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0.01 s
All set-ups
0.01 s
All set-ups
100 Hz
All set-ups
ExpressionLimit
All set-ups
0 ReferenceFeedbackUnit
All set-ups
ExpressionLimit
All set-ups
100 ms
All set-ups
100 Hz
All set-ups
ExpressionLimit
All set-ups
0 ReferenceFeedbackUnit
All set-ups
ExpressionLimit
All set-ups
100 ms
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
1024 N/A
All set-ups
[0] Clockwise
All set-ups
25 s
2 set-ups
0 N/A
All set-ups
0 %
All set-ups
0 %
1 set-up
0 %
All set-ups
0 %
1 set-up
0 %
All set-ups
0 %
1 set-up
Default value
4 set-up
10 s
All set-ups
[0] Off
All set-ups
ExpressionLimit
All set-ups
10 V
All set-ups
0.14 mA
All set-ups
Danfoss A/S © 01/2018 All rights reserved.
TRUE
-
x
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-2
TRUE
-2
x
TRUE
0
x
TRUE
0
x
TRUE
-3
x
TRUE
-3
x
FALSE
-3
TRUE
0
TRUE
0
TRUE
-3
TRUE
-3
FALSE
-3
TRUE
-
TRUE
0
x
TRUE
-
x
TRUE
0
TRUE
-
TRUE
0
FALSE
0
FALSE
-
x
TRUE
0
TRUE
0
TRUE
-2
TRUE
-2
x
TRUE
-2
x
TRUE
-2
TRUE
-2
TRUE
-2
FC 302 only
Change
Conversio
during
n index
operation
TRUE
0
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-5
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint16
Uint32
Uint32
5
5
Int32
Int32
Uint16
Uint32
Uint32
Int32
Int32
Uint16
Uint8
Uint32
Uint8
Uint32
Uint8
Uint32
Uint16
Uint8
Uint16
Uint32
N2
Uint16
N2
Uint16
N2
Uint16
Type
Uint8
Uint8
Int16
Int16
Int16
235