Subaru B9 TRIBECA WX 2007 Manual page 788

Table of Contents

Advertisement

asieps_tobira.book 12 ページ 2012年2月10日 金曜日 午後3時26分
SECURITY AND LOCKS
2. BODY INTEGRATED UNIT
i84
side
8
7
6
5
23
22
21
20
19
18
17
16 15
35
34
33
32
31
30
29
Description
Ignition switch (ON)
Keyless buzzer
Driver's side front door lock actuator
Door and rear gate lock actuator
Keyless entry control module
Rear gate latch switch
Rear door switch RH
Front door switch LH
Ground
Rear gate release switch
Rear gate release actuator
Driver's side front door lock actuator
Driver's side power window main
switch (door lock switch)
Passenger's side door lock switch
Rear door switch LH
Front door switch RH
Power supply
Room light
Power supply
Horn circuit
Turn signal & hazard circuit
Ground
Power supply
Power supply
Key warning switch
Ground
Ground
Keyless Entry System
B281
side
4
3
2
1
7
6
5
4
14
13
12
11
10
9
19
18
17
16
15
28
27
26
25
24
28
27
26
25
Terminal No.
A1 (INPUT)
Battery voltage is present when ignition switch is turned ON.
A6 (OUTPUT)
12 V is present when pressing the LOCK or UNLOCK button of transmitter.
A7 (OUTPUT)
Battery voltage is present when pressing the transmitter LOCK button.
A8 (OUTPUT)
Battery voltage is present when pressing the transmitter UNLOCK button.
A9 (INPUT)
Communication line (Cannot be measured because of digital signal)
A17 (INPUT)
0 V is present when opening the rear gate.
A18 (INPUT)
0 V is present when opening the rear door RH.
A19 (INPUT)
0 V is present when opening the front door LH.
A21
0 V is constantly present.
C22 (OUTPUT)
0 V is present when pressing the rear gate release switch.
The battery voltage is detected for 0.6 seconds when operating the rear
A22 (OUTPUT)
gate release switch.
A23 (OUTPUT)
Battery voltage is present when pressing the transmitter UNLOCK button.
A15
0 V is present when pressing the door lock switch to the LOCK side.
A29
0 V is present when pressing the door lock switch to the UNLOCK side.
A31 (INPUT)
0 V is present when opening the rear door LH.
A32 (INPUT)
0 V is present when opening the front door RH.
A34
Battery voltage is constantly present.
• 0 V is present when pressing the UNLOCK button of transmitter.
B3 (INPUT)
• 0 V is present when opening the door.
B7
Battery voltage is constantly present.
B11 (INPUT)
0 V is present when pressing the panic button of transmitter
B12 (OUTPUT)
0 V is present when pressing the LOCK or UNLOCK button of transmitter.
B22
0 V is constantly present.
C1
Battery voltage is constantly present.
C2
Battery voltage is constantly present.
C7 (INPUT)
Battery voltage is present when inserting the key into ignition switch.
C8
0 V is constantly present.
C9
0 V is constantly present.
SL-12
side
B280
3
2
1
7
6
5
14
13 12
11
10
9
8
20
19
18
17
24
23
22
21
20
30
29
28
Measuring condition
4
3
2
1
16
15
14 13
12
11
10
9
8
27
26
25
24
23
22
21
CS-00273

Advertisement

Table of Contents
loading

Table of Contents