4.3.3

Monitor item list

• Set the monitor to be output to the terminal DA1 (bipolar analog output (0 to 10 VDC voltage output)) in Pr.838 DA1
terminal function selection. The settings of Pr.838 are the same as those of Pr.158 AM terminal function selection. For
the details of Pr.158, refer to the Instruction Manual (Detailed) of the inverter.
• For the following monitor items, values with minus signs can be output from terminal DA1. Setting Pr.290 and Pr.1018 is not
required.
Pr.838
Types of monitor
*1
1
Output frequency
*1
6
Running speed
*2
7
Motor torque
*2
17
Load meter
32
*2
Torque command
33
Torque current command
*3
34
Motor output
Torque monitor
36
(driving/regenerative polarity switching)
46
Motor temperature
54
PID deviation
70
PLC function analog output(SD1301)
87
Remote output value 1
88
Remote output value 2
89
Remote output value 3
90
Remote output value 4
91
PID manipulated variable
94
Second PID deviation
96
Second PID manipulated variable
98
Control circuit temperature
Full-scale value
Pr.55
Value is Pr.55 converted by Pr.37, Pr.144.
Pr.866
Pr.866
Pr.866
*2
Pr.866
Rated motor capacity
Pr.866
*3
Pr.751
100%
100%
1000%
1000%
1000%
1000%
100%
100%
100%
100°C
BIPOLAR ANALOG OUTPUT
4
25