Pulse Monitor - Mitsubishi Electric FR-E800 Instruction Manual

Advertisement

7.6

Pulse monitor

PM
PM
PM
Vector
Vector
Vector
Various pulses can be monitored.
Pr.
Name
430
Pulse monitor selection
B011
*1
Cumulative pulse clear signal
635
selection
M610
*1
Cumulative pulse division
636
scaling factor
M611
*1
638
Cumulative pulse storage
M613
*1
The setting is available when a Vector control compatible option is installed. For the IP67 model, the setting is not available as plug-in options
are not available.
 Pulse monitor selection (Pr.430)
• To show any of pulse conditions as the number of pulses during operation, set "0" in Pr.52 Operation panel main monitor
selection. The output frequency will be displayed.
• Setting "26 to 31" in Pr.52, Pr.774 to Pr.776, Pr.992 (multifunction monitor) changes the electronic gear operation setting
in the case of monitoring pulses. (Refer to
Pr.430 setting
[][][]0
[][][]1
[][][]2
Pulse monitor selection
[][][]3
[][][]4
[][][]5
[]0[][]
For pulse monitor
selection
[]1[][]
0[][][]
For the multifunction
monitor / PLC function
special register
1[][][]
8888
Output frequency display
9999 (initial value)
Initial value
Setting range
0 to 5, 100 to 105, 1000 to
1005, 1100 to 1105
9999
8888, 9999
0
0, 1
1
1 to 16384
0
0, 1
page
348.)
Description
Displays the lower of the position command (accumulated value of
command pulses).
Displays the upper of the position command (accumulated value of
command pulses).
Displays the lower of the current position (accumulated value of feedback
pulses).
Displays the upper of the current position (accumulated value of feedback
pulses).
Displays the lower of the accumulated value of droop pulses.
Displays the upper of the accumulated value of droop pulses.
Displays the value after electronic gear for position command, current
position, or droop pulses to be monitored (pulse monitor).
Displays the value before electronic gear for position command, current
position, or droop pulses to be monitored (pulse monitor).
Displays the value before electronic gear for position command, current
position, or droop pulses to be monitored (multifunction monitor).
Displays the value before electronic gear for position command, current
position, or droop pulses to be monitored (PLC function special register).
Displays the value after electronic gear for position command, current
position, or droop pulses to be monitored (multifunction monitor).
Displays the value after electronic gear for position command, current
position, or droop pulses to be monitored (PLC function special register).
Displays the value after electronic gear for position command, current
position, or droop pulses to be monitored (multifunction monitor).
Displays the value after electronic gear for position command, current
position, or droop pulses to be monitored (PLC function special register).
Displays the value before electronic gear for position command, current
position, or droop pulses to be monitored (multifunction monitor).
Displays the value before electronic gear for position command, current
position, or droop pulses to be monitored (PLC function special register).
Description
Shows the various pulse conditions during
operation as the number of pulses.
Shows the frequency value.
Select the clearing method for the cumulative
pulse monitor.
Set the division scaling factor on the cumulative
pulse for the Vector control compatible option.
Select the processing method for the cumulative
pulse monitor value when the power is turned OFF
or the inverter is reset.
7. Position Control
7.6 Pulse monitor
1
2
3
4
5
6
7
8
9
10
207