Download Print this page

Stack Resiliencylink - Centrecom FS980M/9 Command Reference Manual

Fs980m series fast ethernet managed access switches reference for alliedware plus version 5.4.6-2.x

Advertisement

V
C
S
(VCS
IRTUAL
HASSIS
TACKING

STACK RESILIENCYLINK

stack resiliencylink
Overview
This command configures the resiliency link used by the stack. The interface used
may be either an eth port or is a dedicated VLAN (resiliencylink VLAN) to which
switch ports may become members. This VLAN is dedicated to the resiliency link
function and must not be the stack management VLAN.
stack resiliencylink <interface>
Syntax
no stack resiliencylink
Mode
Global Configuration
Usage
The resiliency-link is only used when a backup member loses connectivity with the
master via the stacking cables. Such a communication loss would occur if:
The resiliency-link allows the backup member to determine if the master is still
present in the network by the reception of healthcheck messages sent by the
master over the resiliency-link interface.
Reply healthcheck messages are received if the master is still online, but the stack
will now split into two different "stubs". The stub containing the existing master
will continue operating as normal. The member in the masterless stub will now use
a "type stack disabled-master" trigger to run a configuration to form a second
temporary stack. This utilizes the remaining stack member's resources without
conflicting directly with the master's configuration. If no "type stack
disabled-master" trigger was configured on the switches, then the masterless stub
member will disable its switch ports.
If no healthcheck messages are received, then the master is assumed to be
completely offline, and so the other stack member can safely take over the master's
configuration.
CAUTION
status of the master under fault conditions. If the resiliency link is not configured, and
the master loses communication with its other stack member, then the stack will
assume the master is NOT present in the network, which could cause network conflicts
if the master is still online.
613-50137-01 Rev A
™) C
TACK
OMMANDS
Parameters
<interface>
a stacking link is removed or fails
two or more stacking link cables are unplugged or fail
the stack master itself fails due to a reboot or power failure
: The purpose of the resiliency link is to enable the backup master to check the
Command Reference for FS980M Series
AlliedWare Plus™ Operating System - Version 5.4.6-2.x
Description
The name of the interface that is connected to the resiliency
link.
This may be either the eth port or the resiliencylink VLAN.
1242

Advertisement

loading