Download Print this page

Type Ping-Poll - Centrecom FS980M/9 Command Reference Manual

Fs980m series fast ethernet managed access switches reference for alliedware plus version 5.4.6-2.x

Advertisement

T
C
RIGGER
OMMANDS
-
TYPE PING
POLL

type ping-poll

Overview
This command configures a trigger that activates when Ping Polling identifies that
a target device's status has changed. This allows you to run a configuration script
when a device becomes reachable or unreachable.
type ping-poll <1-100> {up|down}
Syntax
Mode
Trigger Configuration
To configure trigger 106 to activate when ping poll 12 detects that its target
Example
device is now unreachable, use the following commands:
awplus#
awplus(config)#
awplus(config-trigger)#
Related
show trigger
Commands
trigger
613-50137-01 Rev A
Parameter
Description
<1-100>
The ping poll ID.
up
The trigger activates when ping polling detects that the target is
reachable.
down
The trigger activates when ping polling detects that the target is
unreachable.
configure terminal
trigger 106
Command Reference for FS980M Series
AlliedWare Plus™ Operating System - Version 5.4.6-2.x
type ping-poll 12 down
1673