critical-interval

Overview
This command specifies the time period in seconds between pings when the
polling instance has not received a reply to at least one ping, and when the device
is unreachable.
This command enables the device to quickly observe changes in state, and should
be set to a much lower value than the
The no variant of this command sets the critical interval to the default of one
second.
critical-interval <1-65536>
Syntax
no critical-interval
Default
The default is 1 second.
Mode
Ping-Polling Configuration
Examples
To set the critical interval to 2 seconds for the ping-polling instance 99, use the
commands:
awplus#
awplus(config)#
awplus(config-ping-poll)#
To reset the critical interval to the default of one second for the ping-polling
instance 99, use the commands:
awplus#
awplus(config)#
awplus(config-ping-poll)#
Related
fail-count
Commands
normal-interval
sample-size
show ping-poll
timeout (ping polling)
up-count
613-50137-01 Rev A
Parameter
<1-65536>
configure terminal
ping-poll 99
configure terminal
ping-poll 99
Command Reference for FS980M Series
AlliedWare Plus™ Operating System - Version 5.4.6-2.x
normal-interval
Description
Time in seconds between pings, when the device has failed to
a ping, or the device is unreachable.
critical-interval 2
no critical-interval
command.
1686