Mitsubishi Electric MELSEC iQ-R Series Programming Manual page 1634

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Operand: (s2)
Device
Item
+595
For 120th
module
+596
+597
+598
+599
+600 to
For 121st
+604
module
*1 If a value outside the setting range is set for the appropriate station information setting, the instruction will complete with an error.
*2 The specified number of points is regarded as the number of RX/RY or RWr/RWw points.
Repeat this setting for the total number of slave stations that was set in the control data.
■Reserved station setting data (for master station setting only)
Operand: (s3)
Device
Item
+0 to +7
Station 1 to 120
specification
*1 Make the setting for the station number that was set with the appropriate setting information setting data.
If the specified total number of slave stations does not match the individual station setting data, the total
number of individual stations specified in the total number of slave stations take precedence. Individual station
information which is specified exceeding the total number of slave stations is ignored. Note that 1 is added to
the total number of slave stations when the submaster function enabled/disabled ((s1)+1 bit 3) is enabled (1).
18 CC-LINK IE FIELD NETWORK INSTRUCTIONS
1632
18.7 Setting Parameters
Description
Slave station
Sets the station type.
setting
information
RX/RY offset
Sets the offset value from the head of RX/RY (in units of 16 points).
Number of RX/
Sets the number of RX/RY points.
RY points
• If the station type is master or local: 0 to 2048 points
• If the station type is intelligent device: 0 to 2048 points (in units of 16 points)
• If the station type is remote I/O: 0 to 64 points (in units of 16 points)
• If the station type is remote device: 0 to 128 points (in units of 16 points)
RWr/RWw
Sets the offset value from the start of RWr/RWw (in units of 4 points).
offset
Number of RWr/
Sets the number of RWr/RWw points.
RWw points
• If the station type is master or local: 0 to 256 points (in units of 16 points)
• If the station type is intelligent device: 0 to 1024 points (in units of 4 points)
• If the station type is remote device: 0 to 64 points (in units of 4 points)
Same as above
Description
Specify the reserved station.
*1
• 0: Not specified
• 1: Specified
Each number in the table indicates a station number.
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
(s3)+0
16 15 14 13 12 11 10
(s3)+1
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
(s3)+2
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
(s3)+3
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
(s3)+4
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
(s3)+5
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
(s3)+6
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
(s3)+7
The default parameter specifies that all stations are 0 (not specified).
*2
*2
9
8
7
6
5
4
3
2
120 119 118 117 116 115 114 113
Setting
*1
range
Same as
(s2)+0
*2
0 to 16368
0 to 2048
0 to 64
0 to 128
*2
0 to 8188
0 to 256
0 to 1024
0 to 64
Setting range
Left
1
Set by
User
User
User
User
User
User
Set by
User