Mitsubishi Electric MELSEC iQ-R Series Programming Manual page 1709

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Operand: (s2)
Device
Item
+14,
1st piece (1st
Start device monitored
+15
block)
+16
Number of registered
points
+17
Sending
upon
condition
matching
+18
+19
+20
+21
For system
+22 to
2nd to 10th piece of programmable
+102
controller CPU monitoring setting (2nd to
10th block)
+103
CPU status
Sending
monitoring
upon
+104
setting
condition
+105
(error
matching
monitoring 11th
+106
piece)
+107
(11th block)
+108
+109
+110
+111
For system
• When programmable controller CPU monitoring is canceled
Operand: (s2)
Device
Item
+0
Execution type
+1
Completion status
+2
Request type
+3 to
For system
+111
Description
Specifies the start device monitored of this block.
Specifies the number of registered, or read, points of this block. For a bit
device, specify the number of points in units of words.
• 0: Device not monitored
• 1 or more: Number of registered points
Monitoring
Specifies the monitoring condition for this block.
condition
• 0: Not specified (when sending with a fixed cycle)
• 1 or more: Monitoring conditions
Monitoring
Specifies the monitoring condition value for this block. Specify 0 for
condition
sending with a fixed cycle.
value
• 0 or more: Monitoring conditions
User
Specifies the start pointer of the table where the user frame numbers for
frame
sending upon condition matching have been set.
output
• 0: Not specified (when sending with a fixed cycle)
start
• 1 to 100: Start pointer
pointer
Number of
Specifies the number of user frames that are sent, or output, upon
user
condition matching.
frames
• 0: Not specified (when sending with a fixed cycle)
sent
• 1 to 100: Amount of data sent
Use prohibited
Same row as 1st piece of programmable controller CPU monitoring
setting
Fixed
Specifies the fixed value if the CPU status is monitored.
value
User
Specifies the start pointer of the table where the user frame numbers for
frame
sending upon condition matching have been set.
output
• 0: Not specified (when sending with a fixed cycle)
start
• 1 to 100: Start pointer
pointer
Number of
Specifies the number of user frames that are sent, or output, upon
user
condition matching.
frames
• 0: Not specified (when sending with a fixed cycle)
sent
• 1 to 100: Amount of data sent
Use prohibited
Description
Specifies "0."
Used to store the completion status.
• 0: Normal
• Other than 0: Error (error code)
Specifies the contents of request.
• 3: Cancels programmable controller CPU monitoring.
Use prohibited (not available also for other applications such as programming)
20.11 Registering/Canceling the Programmable Controller CPU Monitoring
Setting range
0 or more
0 or more
Refer to the
following.
 MELSEC
iQ-R Serial
Communication
Module User's
Manual
(Application)
0, 1 to 100
0, 1 to 100
1
0
0
1
5
1
0, 1 to 100
0, 1 to 100
Setting range
0
3
20 SERIAL COMMUNICATION INSTRUCTIONS
Set by
User
User
User
User
20
User
User
User
User
User
User
User
User
User
User
User
Set by
User
System
User
System
1707

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents