Converting Int To Word - Mitsubishi Electric MELSEC iQ-R Series Programming Manual

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

25.20

Converting INT to WORD

INT_TO_WORD(_E)
RnPCPU
RnPCPU
RnCPU RnENCPU
(Process)
(Redundant)
These functions convert a value from INT data type to WORD data type.
Ladder, FBD/LD
[Without EN/ENO]
s
d
Setting data
■Description, type, data type
Argument
Description
EN
Execution condition (TRUE: Executed, FALSE: Not executed)
s (IN)
Input
ENO
Output status (TRUE: Normal, FALSE: Abnormal)
d
Output
Processing details
■Operation processing
• These functions convert the value input to (s) from INT data type to WORD data type, and output the converted value from
(d).
(s)
22136
INT
• Input an INT data type value to (s).
■Operation result
1.
Function without EN/ENO
The operation processing is performed. The operation result is output from (d).
2.
Function with EN/ENO
The execution conditions and operation results will be as follows.
Execution condition
EN
TRUE (executed)
FALSE (not executed)
*1 If the value FALSE is output from ENO, the output data from (d) will be undefined. Create a program so that the undefined value will not
be used in operations.
Operation error
There is no operation error.
RnSFCPU RnSFCPU
(Standard)
(Safety)
[With EN/ENO]
EN
ENO
s
d
(d)
5678H
WORD
Operation result
ENO
TRUE
*1
FALSE
Structured text
[Without EN/ENO]
d:=INT_TO_WORD(s);
[With EN/ENO]
d:=INT_TO_WORD_E(EN,ENO,s);
Type
Input variable
Input variable
Output variable
Output variable
(d)
Operation result output value
Undefined value
25 TYPE CONVERSION FUNCTIONS
25.20 Converting INT to WORD
25
Data type
BOOL
INT
BOOL
WORD
1815