Mitsubishi Electric MELSEC iQ-R Series Programming Manual page 1452

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Range of available channel numbers
The range of own station channels that can be specified by the network common instructions varies depending on the
module.
The following table summarizes the ranges of channels that can be specified by instructions for individual modules.
■Available channel numbers
Instruction
RJ71GP21-SX
symbol
READ, SREAD,
1 to 10
WRITE, SWRITE
SEND, RECV,
1 to 8
RECVS, REQ
RRUN, RSTOP,
1 to 8
RTMRD, RTMWR
REMFR, REMTO,
REMFRD,
REMTOD
Instruction
RJ71EN71
symbol
RJ71EN71(E+E)
PORT1
READ, SREAD,
1 to 8
WRITE, SWRITE
SEND, RECV,
1 to 8
RECVS, REQ
RRUN, RSTOP,
RTMRD, RTMWR
REMFR, REMTO,
REMFRD,
REMTOD
Instruction
RnENCPU (network part)
symbol
_RJ71EN71(E+CCIEC)
PORT1
READ, SREAD,
1 to 8
WRITE, SWRITE
SEND, RECV,
1 to 8
RECVS, REQ
RRUN, RSTOP,
RTMRD, RTMWR
REMFR, REMTO,
REMFRD,
REMTOD
*1 The own station channel numbers specified by REMFR, REMTO, REMFRD, and REMTOD instructions can be used in combination with
the own station channel numbers specified by link dedicated instructions.
*2 The range of channel numbers of an Ethernet module varies depending on the combination of network types at PORT1 and PORT2.
• RJ71EN71(E+E): PORT1 and PORT2 are "Ethernet".
• RJ71EN71(E+CCIEC): PORT1 is "Ethernet" and PORT2 is "CC-Link IE Controller Network".
• RJ71EN71(CCIEC): PORT1 and PORT2 are "CC-Link IE Controller Network".
• RJ71EN71(E+CCIEF): PORT1 is "Ethernet" and PORT2 is "CC-Link IE Field Network".
• RJ71EN71(CCIEF): PORT1 and PORT2 are "CC-Link IE Field Network".
• RJ71EN71(Q): PORT1 is "Q-compatible Ethernet". (PORT2 cannot be used.)
*3 The range of channel numbers of the RnENCPU (network part) varies depending on the combination of network types at PORT1 and
PORT2.
• _RJ71EN71(E+CCIEC): PORT1 is "Ethernet" and PORT2 is "CC-Link IE Controller Network".
• _RJ71EN71(CCIEC): PORT1 and PORT2 are "CC-Link IE Controller Network".
• _RJ71EN71(E+CCIEF): PORT1 is "Ethernet" and PORT2 is "CC-Link IE Field Network".
• _RJ71EN71(CCIEF): PORT1 and PORT2 are "CC-Link IE Field Network".
15 NETWORK COMMON INSTRUCTIONS
1450
*2
RJ71EN71(E+CCIEC)
PORT2
PORT1
PORT2
11 to 18
1 to 8
11 to 18
11 to 18
1 to 8
11 to 18
11 to 18
*3
_RJ71EN71(CCIEC)
PORT2
PORT1/PORT2
11 to 18
1 to 8
11 to 18
1 to 8
11 to 18
1 to 8
RJ71GF11-T2
1, 2
1, 2
*1
1 to 32
RJ71EN71(CCIEC)
RJ71EN71(E+CCIEF)
PORT1/PORT2
PORT1
1 to 8
1 to 8
1 to 8
1 to 8
1 to 8
_RJ71EN71(E+CCIEF)
PORT1
1 to 8
1 to 8
RJ71EN71
(CCIEF)
PORT2
PORT1/
PORT2
11 to 18
1 to 8
11 to 18
1 to 8
*1
*1
1 to 32
1 to 32
_RJ71EN71(CCIEF)
PORT2
PORT1/PORT2
11 to 18
1 to 8
11 to 18
1 to 8
*1
*1
1 to 32
1 to 32
RJ71EN71
(Q)
PORT1
1 to 8
1 to 8