Recipe read

Z(P).RCPREAD
RnPCPU
RnCPU RnENCPU
(Process)
These instructions reads device values of the specified recipe file in the SD memory card to the CPU module.
Ladder
(U)
FBD/LD
EN
ENO
U
d
s
■Execution condition
Instruction
Z.RCPREAD
ZP.RCPREAD
Setting data
■Description, range, data type
Operand
Description
(U)
Start I/O number (first three digits in four-digit hexadecimal
representation) of a module
(s)
Start device where control data is stored
(d)
Device that turns on for one scan upon completion of the
instruction
When the instruction completes with an error, (d)+1 also
turns on.
EN
Execution condition
ENO
Execution result
*1 When specifying setting data by using a label, define an array to secure enough operation area and specify an element of the array
label.
The local device and the file register for each program are not available for setting data.
■Applicable devices
Operand
Bit
X, Y, M, L,
SM, F, B, SB,
FX, FY
(U)
(s)
*1
(d)
*1 FX and FY cannot be used.
*2 FD cannot be used.
*3 T, ST, C, and FD cannot be used.
23 High Speed Data Logger Module Instructions
1784
23.1 File Access Instructions
RnPCPU
RnSFCPU RnSFCPU
(Redundant)
(Standard)
(Safety)
(s)
(d)
Execution condition
Word
J\
T, ST, C, D, W,
SD, SW, FD, R,
ZR, RD
*2
*3
ST
ENO:=Z_RCPREAD(EN,U,s,d);
ENO:=ZP_RCPREAD(EN,U,s,d);
Range
00H to FEH
Page 1785 Control data
Double word
U\G, J\,
Z
LT, LST,
U3E\(H)G
LC
Data type
Data type (label)
String
ANY16_OR_STRING_
SINGLE
Device name
ANY16
Bit
ANYBIT_ARRAY
(Number of elements: 2)
Bit
BOOL
Bit
BOOL
Indirect
Constant
specification
LZ
K, H E
*1
Others
(U)
$