Processing details
• This instruction writes the data from the start device (s5) of the own station to the buffer memory area ((s4) and later) of the
intelligent device station or the remote device station for the specified number of words (n). Specify the target station by
using (J), (s2), and (s3). The completion device (d) turns on upon completion of the instruction.
[Own station]
CPU module
(s5)
REMTO
CH: Channel
• The execution status and the completion status of the REMTO instruction can be checked with the completion device (d)
and the completion status indication device (d)+1.
• Completion device (d)
This device turns on during END processing of the scan where the REMTO instruction completes, and turns off during the next END processing.
• Completion status indication device (d)+1
This device turns on or off depending on the completion status of the REMTO instruction.
When completed successfully: The device remains off.
When completed with an error: The device turns on during END processing of the scan where the REMTO instruction completes, and turns off during the next
END processing.
CC-Link IE Field
Network master/local module
CH1
·
CHn
·
CH32
18.2 Writing Data to the Intelligent Device Station/Remote Device Station (16-bit Address Specified)
[Target station]
Head module
(s4)
18 CC-LINK IE FIELD NETWORK INSTRUCTIONS
Intelligent function module
(n)
word(s)
1607
18