Mitsubishi Electric MELSEC iQ-R Series Programming Manual page 1753

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

• For R60DAV8, R60DAI8, R60DA8-G
Operand: (s)
Device
Item
+0
System area
+1
Completion status
*2
+2
Save data type setting
+3
System area
+4
CH1 Factory default setting offset value
+5
CH1 Factory default setting gain value
+6
CH2 Factory default setting offset value
+7
CH2 Factory default setting gain value
+8
CH3 Factory default setting offset value
+9
CH3 Factory default setting gain value
+10
CH4 Factory default setting offset value
+11
CH4 Factory default setting gain value
+12
CH5 Factory default setting offset value
+13
CH5 Factory default setting gain value
+14
CH6 Factory default setting offset value
+15
CH6 Factory default setting gain value
+16
CH7 Factory default setting offset value
+17
CH7 Factory default setting gain value
+18
CH8 Factory default setting offset value
+19
CH8 Factory default setting gain value
+20
CH1 User range setting offset value
+21
CH1 User range setting gain value
+22
CH2 User range setting offset value
+23
CH2 User range setting gain value
+24
CH3 User range setting offset value
+25
CH3 User range setting gain value
+26
CH4 User range setting offset value
+27
CH4 User range setting gain value
+28
CH5 User range setting offset value
+29
CH5 User range setting gain value
+30
CH6 User range setting offset value
+31
CH6 User range setting gain value
+32
CH7 User range setting offset value
+33
CH7 User range setting gain value
+34
CH8 User range setting offset value
+35
CH8 User range setting gain value
+36
System area
*2 For the R60DAV8 and the R60DAI8, this area corresponds to System area and so is not available.
Description
The instruction completion status is stored.
• 0: Completed successfully
• Other than 0: Completed with an error (error code)
Used to store the set value that was set for Save data type
setting (s)+2 in the G(P).OGLOAD instruction.
• 0H: User range setting 1 (current specification)
• 1H: User range setting 2 (voltage specification)
• 2H: User range setting 3 (voltage specification)
b15
b14
b13
b12
b11
b10
b9
b8
b7
CH8
CH7
CH6
CH5
CH4
Setting range
0000H to
AAAAH
b6
b5
b4
b3
b2 b1 b0
CH3
CH2
CH1
21 A/D CONVERSION INSTRUCTIONS
21.3 Restoring the User Range Setting Values
Set by
System
System
System
21
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
1751

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents