• When the read target module has a model name, the model name is stored in the 2nd word and later according to the
following rules.
• The name occupies nine words.
• The name is stored in ASCII characters.
• 00H is stored in the 18th character.
• If the number of characters is less than 17, 00H is stored in the remaining characters.
• The model name held by a module or a unit is stored. (Note that it may differ from the one written on the rating plate.)
Ex.
The following table lists examples of model names stored.
Target module
Remote head module
I/O module
Network module
If the model name in the I/O assignment setting and that of the mounted module differ, the model name held
by the mounted module is stored.
• When the read target module does not have a model name, the character string is stored in the 2nd word and later
according to the following rules.
• The name occupies nine words.
• The name is stored in ASCII characters.
• 00H is stored in the 18th character.
• If the number of characters is less than 17, 00H is stored in the remaining characters.
• A character string consisting of a combination of "character string indicating the module type" and "character string indicating the number of points" is stored.
Ex.
The following table lists examples of character strings stored (module type).
Target module
Input module
Output module
I/O combined module
Intelligent function module
The following table lists examples of character strings stored (number of points).
Number of points
16 points
32 points
48 points
64 points
128 points
256 points
512 points
1024 points
If the number of points in the I/O assignment setting and that of the mounted module differ, the number of
points of the mounted module is stored.
Operation error
Error code
Description
((s)+1)
 MELSEC iQ-R CC-Link IE Field Network User's Manual (Application)
D000H to DFFFH
Character string example (module type)
RJ72GF15-T2
INPUT_16
RJ71EN71(E+E)
Model name example
INPUT_16
OUTPUT_32
MIXED_64
INTELLIGENT_128
Character string example (number of points)
_16
_32
_48
_64
_128
_256
_512
_1024
18 CC-LINK IE FIELD NETWORK INSTRUCTIONS