Mitsubishi Electric MELSEC iQ-R Series Programming Manual page 1754

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

• For R60TD8-G
Operand: (s)
Device
Item
+0
System area
+1
Completion status
+2
System area
+3
System area
+4
CH1 Factory default setting offset value (L)
+5
CH1 Factory default setting offset value (H)
+6
CH1 Factory default setting gain value (L)
+7
CH1 Factory default setting gain value (H)
+8
CH1 User range setting offset value (L)
+9
CH1 User range setting offset value (H)
+10
CH1 User range setting gain value (L)
+11
CH1 User range setting gain value (H)
+12
CH1 User range setting
thermoelectromotive force offset value (L)
+13
CH1 User range setting
thermoelectromotive force offset value (H)
+14
CH1 User range setting
thermoelectromotive force gain value (L)
+15
CH1 User range setting
thermoelectromotive force gain value (H)
+16
CH2 Factory default setting offset value (L)
+17
CH2 Factory default setting offset value (H)
+18
CH2 Factory default setting gain value (L)
+19
CH2 Factory default setting gain value (H)
+20
CH2 User range setting offset value (L)
+21
CH2 User range setting offset value (H)
+22
CH2 User range setting gain value (L)
+23
CH2 User range setting gain value (H)
+24
CH2 User range setting
thermoelectromotive force offset value (L)
+25
CH2 User range setting
thermoelectromotive force offset value (H)
+26
CH2 User range setting
thermoelectromotive force gain value (L)
+27
CH2 User range setting
thermoelectromotive force gain value (H)
+28
CH3 Factory default setting offset value (L)
+29
CH3 Factory default setting offset value (H)
+30
CH3 Factory default setting gain value (L)
+31
CH3 Factory default setting gain value (H)
+32
CH3 User range setting offset value (L)
+33
CH3 User range setting offset value (H)
+34
CH3 User range setting gain value (L)
+35
CH3 User range setting gain value (H)
+36
CH3 User range setting
thermoelectromotive force offset value (L)
+37
CH3 User range setting
thermoelectromotive force offset value (H)
+38
CH3 User range setting
thermoelectromotive force gain value (L)
+39
CH3 User range setting
thermoelectromotive force gain value (H)
21 A/D CONVERSION INSTRUCTIONS
1752
21.3 Restoring the User Range Setting Values
Description
The instruction completion status is stored.
• 0: Completed successfully
• Other than 0: Completed with an error (error code)
Setting range
Set by
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents