■Error invalid station setting data (for master station setting only)
Operand: (s4)
Device
Item
+0 to +7
Station 1 to 120
*1
specification
*1 Make the setting for the station number that was set with the appropriate setting information setting data.
If both the error invalid and reserved stations are specified for the same station, the reserved station setting will take priority.
Any station numbers outside the range specified by the number of slave stations or other than those specified
in the individual station information settings are ignored even if they are specified as reserved stations or
temporary error invalid stations.
Processing details
• This instruction sets the parameters in the CC-Link IE Field Network master and local modules.
[Own station]
CPU module
• The execution status and the completion status of the G(P).CCPASET instruction can be checked with the completion
device (d) and the completion status indication device (d)+1.
• Completion device (d)
This device turns on during END processing of the scan where the G(P).CCPASET instruction completes, and turns off during the next END processing.
• Completion status indication device (d)+1
This device turns on or off depending on the completion status of the G(P).CCPASET instruction.
When completed successfully: The device remains off.
When completed with an error: The device turns on during END processing of the scan where the G(P).CCPASET instruction completes, and turns off during
the next END processing.
Description
Specify the error invalid station.
• 0: Not specified
• 1: Specified
Each number in the table indicates a station number.
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
(s4)+0
16 15 14 13 12 11 10
(s4)+1
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
(s4)+2
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
(s4)+3
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
(s4)+4
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
(s4)+5
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
(s4)+6
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
(s4)+7
The default parameter specifies that all stations are 0 (not specified).
CC-Link IE Field Network
master/local module
CCPASET
Setting parameters
9
8
7
6
5
4
3
2
1
120 119 118 117 116 115 114 113
18 CC-LINK IE FIELD NETWORK INSTRUCTIONS
Setting range
Set by
Left
User
1633
18.7 Setting Parameters