Mitsubishi Electric MELSEC iQ-R Series Programming Manual page 1623

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

■Applicable devices
Operand
Bit
X, Y, M, L,
SM, F, B, SB,
FX, FY
(J/U)
J(P).S
INFTY
RD
G(P).
SINFT
YRD
(s)
(d1)
*1
(d2)
*1 FX and FY cannot be used.
*2 FD cannot be used.
*3 T, ST, C, and FD cannot be used.
■Control data
Operand: (s)
Device
Item
+0
Error completion type
+1
Completion status
*1
+2
Own station channel
+3 to +4
+5
Target station number
+6
+7
Number of resends
+8
Arrival monitoring time
+9 to +10
+11
Clock setting flag
Word
J\
T, ST, C, D, W,
U\G, J\,
SD, SW, FD, R,
U3E\(H)G
ZR, RD
*2
*2
*3
Description
...
b15
b8
b7
0
(2) (1)
(1) Error completion type (bit 7)
Specify whether to set data at completion with an error.
• 0: Do not set data at completion with an error in (s)+12 and later.
• 1: Set data at completion with an error in (s)+12 and later.
(2) Arrival check time setting (bit 8)
• 0: 1s units
• 1: 100ms units
The instruction completion status is stored.
• 0: Normal
• Other than 0: Error (error code)
Specify the channel to be used by own station.
Not used
Specify the station number of the target station.
Not used
■Before instruction execution
Specify the number of resends to be performed if the instruction is not completed
within the monitoring time specified by (s)+8.
• 0 to 15 (times)
■At completion of instruction
The number of resends performed (result) is stored.
• 0 to 15 (times)
Specify the monitoring time until completion of processing. If processing is not
completed within the monitoring time, the request is resent by the number of
resends specified in (s)+7.
■When "0" is specified in bit 8 of (s)+0
• 0: 10s
• 1 to 32767: 1 to 32767s
■When "1" is specified in bit 8 of (s)+0
• 0: 10s
• 1 to 65535: 1 to 65535  100ms
Not used
The validity status (valid or invalid) of the data in (s)+12 and later is stored. Note that
the data in (s)+12 and later is not cleared even when the instruction is completed
successfully.
• 0: Invalid
• 1: Valid
18.5 Reading the Module Model Information of an Intelligent Device Station
Double word Indirect
specification
Z LT, LST,
LZ
LC
 
 
 
 
 
...
b0
0
18 CC-LINK IE FIELD NETWORK INSTRUCTIONS
Constant
Others
K, H E $
J
U
  
  
  
  
  
Setting range
Set by
0000H
User
0080H
0100H
0180H
System
1 to 32
User
System
1 to 120
User
System
0 to 15
User/
system
0 to 65535
User
System
System
1621