Reading receive data (for interrupt programs)

G.SOCRCVS
RnPCPU
RnCPU RnENCPU
(Process)
This instruction reads receive data from the external device through socket communications (for interrupt programs).
Ladder
(U)
FBD/LD
EN
ENO
U
d
s
■Execution condition
Instruction
G.SOCRCVS
Setting data
■Description, range, data type
Operand
Description
(U)
Start I/O number (first three digits in four-digit hexadecimal
representation) of own station or own node
(s)
Connection No.
(d)
Own station start device for storing the receive data
EN
Execution condition
ENO
Execution result
*1 When specifying setting data by using a label, define an array to secure enough operation area and specify an element of the array
label.
■Applicable devices
Operand
Bit
X, Y, M, L,
SM, F, B, SB,
FX, FY
(U)
*1
(s)
(d)
*1 FX and FY cannot be used.
*2 FD cannot be used.
16 ETHERNET INSTRUCTIONS
1550
16.2 Socket Communications Instructions
RnPCPU
RnSFCPU RnSFCPU
(Redundant)
(Standard)
(Safety)
(s)
(d)
Execution condition
Word
J\
T, ST, C, D, W,
SD, SW, FD, R,
ZR, RD
*2
*2
ST
ENO:=G_SOCRCVS(EN,U,s,d);
Range
00H to FEH
17 to 128
(17 to 64: Port 1 socket
communications, 65 to 128:
Port 2 socket communications)
Double word
U\G, J\,
Z
LT, LST,
U3E\(H)G
LC
Data type
Data type (label)
16-bit unsigned binary
ANY16
16-bit unsigned binary
ANY16
Device name
ANY16
Bit
BOOL
Bit
BOOL
Indirect
Constant
specification
LZ
K, H
E
*1
Others
(U)
$