Mitsubishi Electric MELSEC iQ-R Series Programming Manual page 2023

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Instruction name
Condition
ANDDT<
When not executed
When compared with the specified date: Continuity
When compared with the specified date: Non-continuity
When compared with the current date: Continuity
When compared with the current date: Non-continuity
ANDDT>=
When not executed
When compared with the specified date: Continuity
When compared with the specified date: Non-continuity
When compared with the current date: Continuity
When compared with the current date: Non-continuity
ORDT=
When not executed
When compared with the specified date: Continuity
When compared with the specified date: Non-continuity
When compared with the current date: Continuity
When compared with the current date: Non-continuity
ORDT<>
When not executed
When compared with the specified date: Continuity
When compared with the specified date: Non-continuity
When compared with the current date: Continuity
When compared with the current date: Non-continuity
ORDT>
When not executed
When compared with the specified date: Continuity
When compared with the specified date: Non-continuity
When compared with the current date: Continuity
When compared with the current date: Non-continuity
ORDT<=
When not executed
When compared with the specified date: Continuity
When compared with the specified date: Non-continuity
When compared with the current date: Continuity
When compared with the current date: Non-continuity
ORDT<
When not executed
When compared with the specified date: Continuity
When compared with the specified date: Non-continuity
When compared with the current date: Continuity
When compared with the current date: Non-continuity
ORDT>=
When not executed
When compared with the specified date: Continuity
When compared with the specified date: Non-continuity
When compared with the current date: Continuity
When compared with the current date: Non-continuity
LDTM=
When compared with the specified time: Continuity
When compared with the specified time: Non-continuity
When compared with the current time: Continuity
When compared with the current time: Non-continuity
LDTM<>
When compared with the specified time: Continuity
When compared with the specified time: Non-continuity
When compared with the current time: Continuity
When compared with the current time: Non-continuity
LDTM>
When compared with the specified time: Continuity
When compared with the specified time: Non-continuity
When compared with the current time: Continuity
When compared with the current time: Non-continuity
Processing time (s)
Minimum
Maximum
0.00588
2.600
9.400
2.600
9.600
4.800
16.200
4.900
15.200
0.00588
2.700
9.900
2.700
9.700
4.900
14.600
4.900
14.900
0.00588
2.700
9.800
2.600
9.800
4.800
15.600
4.800
15.400
0.00588
2.800
10.000
2.700
10.100
4.700
15.900
4.800
15.600
0.00588
2.800
10.000
2.700
10.000
4.800
15.600
4.800
15.700
0.00588
2.700
9.800
2.600
10.000
4.900
15.000
4.900
15.000
0.00588
2.800
10.200
2.700
10.100
4.800
15.500
4.900
15.400
0.00588
2.800
9.500
2.800
9.600
4.700
14.500
4.700
14.900
2.900
9.500
2.900
9.500
4.700
15.600
4.700
14.900
2.600
9.200
2.600
9.300
4.900
14.500
4.800
14.500
2.600
9.200
2.600
9.300
4.800
14.600
4.900
14.700
Appendix 1 Instruction Processing Time
A
APPX
2021

Hide quick links:

Advertisement

Table of Contents
loading