• For R60TD8-G
Operand: (s)
Device
Item
+0
System area
+1
Completion status
+2
System area
+3
System area
+4
CH1 Factory default setting offset value (L)
+5
CH1 Factory default setting offset value (H)
+6
CH1 Factory default setting gain value (L)
+7
CH1 Factory default setting gain value (H)
+8
CH1 User range setting offset value (L)
+9
CH1 User range setting offset value (H)
+10
CH1 User range setting gain value (L)
+11
CH1 User range setting gain value (H)
+12
CH1 User range setting
thermoelectromotive force offset value (L)
+13
CH1 User range setting
thermoelectromotive force offset value (H)
+14
CH1 User range setting
thermoelectromotive force gain value (L)
+15
CH1 User range setting
thermoelectromotive force gain value (H)
+16
CH2 Factory default setting offset value (L)
+17
CH2 Factory default setting offset value (H)
+18
CH2 Factory default setting gain value (L)
+19
CH2 Factory default setting gain value (H)
+20
CH2 User range setting offset value (L)
+21
CH2 User range setting offset value (H)
+22
CH2 User range setting gain value (L)
+23
CH2 User range setting gain value (H)
+24
CH2 User range setting
thermoelectromotive force offset value (L)
+25
CH2 User range setting
thermoelectromotive force offset value (H)
+26
CH2 User range setting
thermoelectromotive force gain value (L)
+27
CH2 User range setting
thermoelectromotive force gain value (H)
+28
CH3 Factory default setting offset value (L)
+29
CH3 Factory default setting offset value (H)
+30
CH3 Factory default setting gain value (L)
+31
CH3 Factory default setting gain value (H)
+32
CH3 User range setting offset value (L)
+33
CH3 User range setting offset value (H)
+34
CH3 User range setting gain value (L)
+35
CH3 User range setting gain value (H)
+36
CH3 User range setting
thermoelectromotive force offset value (L)
+37
CH3 User range setting
thermoelectromotive force offset value (H)
+38
CH3 User range setting
thermoelectromotive force gain value (L)
+39
CH3 User range setting
thermoelectromotive force gain value (H)
Description
The instruction completion status is stored.
• 0: Completed successfully
• Other than 0: Completed with an error (error code)
Setting range
21 A/D CONVERSION INSTRUCTIONS
21.2 Reading the User Range Setting Values
Set by
System
System
System
System
System
System
System
21
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System