36.4

Counter Function Block

COUNTER_FB_M
RnPCPU
RnPCPU
RnCPU RnENCPU
(Process)
(Redundant)
This function block starts counting up when the execution condition is satisfied.
Ladder, FBD/LD
s1
d1
s2
d2
s3
Setting data
■Description, type, data type
Argument
Description
s1 (Coil)
Execution condition (TRUE: Executed, FALSE: Not executed)
s2 (Preset)
Counter setting value
s3 (ValueIn)
Initial counter value
d1 (ValueOut)
Current counter value
d2 (Status)
Output
RnSFCPU RnSFCPU
(Standard)
(Safety)
Structured text
Instance name(Coil:=s1,Preset:=s2,ValueIn:=s3,ValueOut:=d1,Status:=d2);
Type
Input variable
Input variable
Input variable
Output variable
Output variable
36 COUNTER/TIMER FUNCTION BLOCKS
Data type
BOOL
INT
INT
ANY16
BOOL