Mitsubishi Electric MELSEC iQ-R Series Programming Manual page 1483

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Operand: (s1)
Device
Item
+8
Arrival monitoring time
+9
Write data length
+10
Not used
+11
Clock setting flag
+12
Clock data
(Set only in an
abnormal state)
+13
+14
+15
+16
Error detection network
number
+17
Error-detected station
number
Description
[CC-Link IE Controller Network or CC-Link IE Field Network]
Specify the monitoring time until completion of processing. If processing is not
completed within the monitoring time, the request is resent by the number of
resends specified in (s1)+7.
■When "0" is specified in bit 8 of (s1)+0
• 0: 10s
• 1 to 32767: 1 to 32767s
■When "1" is specified in bit 8 of (s1)+0
• 0: 10s
• 1 to 65535: 1 to 65535100ms
[Ethernet]
Specify the monitoring time until completion of processing. If processing is not
completed within the monitoring time, the request is resent by the number of
resends specified in (s1)+7.
■When "0" is specified in bit 8 of (s1)+0
Specify the TCP resend timer value or greater for the monitoring time till completion
of processing.
• 0 to (TCP resend timer value): The TCP resend timer value is assumed as the
monitoring time.
• (TCP resend timer value + 1) to 16383: (TCP resend timer value + 1) to 16383s
■When "1" is specified in bit 8 of (s1)+0
• 0: 10s
• 1 to 65535: 1 to 65535100ms
Specify the number of words to be written.
■Writing to RCPU, QCPU, or LCPU
• Channels 1 to 8 are used: 1 to 960 (words)
• Channels 9 and 10 are used: 1 to 8192 (words)
■Writing to QnACPU
• 1 to 480 (words)
The validity status (valid or invalid) of the data in (s1)+12 and later is stored. Note
that the data in (s1)+12 and later is not cleared even when the instruction is
completed successfully.
• 0: Invalid
• 1: Valid
Upper 8 bits: Month (01H to 12H)
Lower 8 bits: Lower 2 digits of year (00H to 99H)
Upper 8 bits: Hour (00H to 23H)
Lower 8 bits: Day (01H to 31H)
Upper 8 bits: Second (00H to 59H)
Lower 8 bits: Minute (00H to 59H)
Upper 8 bits: Year (00H to 99H: Upper two digits of the year)
Lower 8 bits: Day of the week (00H (Sun.) to 06H (Sat.))
The network number of the station in which an error was detected is stored. (No
information is stored if an error is detected in the own station.)
• 1 to 239 (Network number)
The station number of the station where an error was detected is stored. (No
information is stored if an error is detected in the own station.)
[Ethernet or CC-Link IE Controller Network]
• 1 to 120: Station number
[CC-Link IE Field Network]
• 125: Master station
• 1 to 120: Local station, intelligent device station, submaster station
Setting range
0 to 65535
0 to 65535
1 to 8192
1 to 239
1 to 120,
125
15 NETWORK COMMON INSTRUCTIONS
15.1 Link Dedicated Instructions
Set by
User
User
User
15
System
System
System
System
System
System
System
1481