Mitsubishi Electric MELSEC iQ-R Series Programming Manual page 1751

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

• For R60ADV8, R60ADI8, R60AD8-G
Operand: (s)
Device
Item
+0
System area
+1
Completion status
*1
+2
Save data type setting
+3
System area
+4
CH1 Factory default setting offset value (L)
+5
CH1 Factory default setting offset value (H)
+6
CH1 Factory default setting gain value (L)
+7
CH1 Factory default setting gain value (H)
+8
CH2 Factory default setting offset value (L)
+9
CH2 Factory default setting offset value (H)
+10
CH2 Factory default setting gain value (L)
+11
CH2 Factory default setting gain value (H)
+12
CH3 Factory default setting offset value (L)
+13
CH3 Factory default setting offset value (H)
+14
CH3 Factory default setting gain value (L)
+15
CH3 Factory default setting gain value (H)
+16
CH4 Factory default setting offset value (L)
+17
CH4 Factory default setting offset value (H)
+18
CH4 Factory default setting gain value (L)
+19
CH4 Factory default setting gain value (H)
+20
CH5 Factory default setting offset value (L)
+21
CH5 Factory default setting offset value (H)
+22
CH5 Factory default setting gain value (L)
+23
CH5 Factory default setting gain value (H)
+24
CH6 Factory default setting offset value (L)
+25
CH6 Factory default setting offset value (H)
+26
CH6 Factory default setting gain value (L)
+27
CH6 Factory default setting gain value (H)
+28
CH7 Factory default setting offset value (L)
+29
CH7 Factory default setting offset value (H)
+30
CH7 Factory default setting gain value (L)
+31
CH7 Factory default setting gain value (H)
+32
CH8 Factory default setting offset value (L)
+33
CH8 Factory default setting offset value (H)
+34
CH8 Factory default setting gain value (L)
+35
CH8 Factory default setting gain value (H)
+36
CH1 User range setting offset value (L)
+37
CH1 User range setting offset value (H)
+38
CH1 User range setting gain value (L)
+39
CH1 User range setting gain value (H)
+40
CH2 User range setting offset value (L)
+41
CH2 User range setting offset value (H)
+42
CH2 User range setting gain value (L)
+43
CH2 User range setting gain value (H)
+44
CH3 User range setting offset value (L)
Description
The instruction completion status is stored.
• 0: Completed successfully
• Other than 0: Completed with an error (error code)
Used to store the set value that was set for Save data type
setting (s)+2 in the G(P).OGLOAD instruction.
• 0: Voltage specification
• 1: Current specification
...
b15
b7
0
CH8
CH7
Setting range
0000H to 00FFH
b6
b5
b4
b3
b2 b1 b0
CH6
CH5
CH4
CH3 CH2 CH1
21 A/D CONVERSION INSTRUCTIONS
21.3 Restoring the User Range Setting Values
Set by
System
System
System
System
21
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
1749

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents