Mitsubishi Electric MELSEC iQ-R Series Programming Manual page 2021

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Instruction name
Condition
DBCLOSE
When executed (for the programmable controller CPU with firmware version
earlier than "28")
When executed (for the programmable controller CPU with firmware version "28"
or later)
DBINSERT
(s3)=1 (for the programmable controller CPU with firmware version earlier than
"28")
(s3)=16 (for the programmable controller CPU with firmware version earlier than
"28")
(s3)=1 (for the programmable controller CPU with firmware version "28" or later)
(s3)=16 (for the programmable controller CPU with firmware version "28" or later)
DBUPDATE
(s3)=1 (for the programmable controller CPU with firmware version earlier than
"28")
(s3)=16 (for the programmable controller CPU with firmware version earlier than
"28")
(s3)=1 (for the programmable controller CPU with firmware version "28" or later)
(s3)=16 (for the programmable controller CPU with firmware version "28" or later)
DBSELECT
(s3)=1 (for the programmable controller CPU with firmware version earlier than
"28")
(s3)=16 (for the programmable controller CPU with firmware version earlier than
"28")
(s3)=1 (for the programmable controller CPU with firmware version "28" or later)
(s3)=16 (for the programmable controller CPU with firmware version "28" or later)
DBDELETE
(s3)=1 (for the programmable controller CPU with firmware version earlier than
"28")
(s3)=2 (for the programmable controller CPU with firmware version earlier than
"28")
(s3)=1 (for the programmable controller CPU with firmware version "28" or later)
(s3)=2 (for the programmable controller CPU with firmware version "28" or later)
DBIMPORT
When executed (for the programmable controller CPU with firmware version
earlier than "28")
When executed (for the programmable controller CPU with firmware version "28"
or later)
DBEXPORT
When executed (for the programmable controller CPU with firmware version
earlier than "28")
When executed (for the programmable controller CPU with firmware version "28"
or later)
DBTRANS
When executed (for the programmable controller CPU with firmware version
earlier than "28")
When executed (for the programmable controller CPU with firmware version "28"
or later)
DBCOMMIT
When executed (for the programmable controller CPU with firmware version
earlier than "28")
When executed (for the programmable controller CPU with firmware version "28"
or later)
DBROLBAK
When executed (for the programmable controller CPU with firmware version
earlier than "28")
When executed (for the programmable controller CPU with firmware version "28"
or later)
RSET
QDRSET
ZRRDB
ZRWRB
ADRSET
DATERD
DATEWR
DATE+
No carry
Carry
Processing time (s)
Minimum
Maximum
11.500
13.100
13.300
18.300
25.400
28.900
46.400
50.100
23.300
29.100
40.200
45.800
31.700
34.700
49.300
52.900
29.900
35.900
46.900
53.200
32.100
35.300
51.600
55.000
32.800
38.300
48.900
55.200
26.000
29.900
27.400
31.200
24.800
30.900
26.600
32.500
16.200
19.200
17.800
22.400
16.000
19.000
17.300
22.500
11.400
13.000
12.800
18.500
11.600
13.000
12.800
18.500
11.500
12.900
12.800
18.400
1.800
6.300
65.100
92.100
1.600
2.900
1.700
3.200
1.100
2.000
3.400
10.700
12.200
37.400
3.300
6.800
3.400
6.500
Appendix 1 Instruction Processing Time
A
APPX
2019

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents