Mitsubishi Electric MELSEC iQ-R Series Programming Manual page 1619

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Processing details
• This instruction writes the data from the start device (s5) of the own station to the buffer memory area ((s4) and later) of the
intelligent device station or the remote device station for the specified number of words (n). Specify the target station by
using (J), (s2), and (s3). The completion device (d) turns on upon completion of the instruction.
[Own station]
CPU module
(s5)
REMTOD
CH: Channel
• The execution status and the completion status of the REMTOD instruction can be checked with the completion device (d)
and the completion status indication device (d)+1.
• Completion device (d)
This device turns on during END processing of the scan where the REMTOD instruction completes, and turns off during the next END processing.
• Completion status indication device (d)+1
This device turns on or off depending on the completion status of the REMTOD instruction.
When completed successfully: The device remains off.
When completed with an error: The device turns on during END processing of the scan where the REMTOD instruction completes, and turns off during the next
END processing.
[Target station]
CC-Link IE Field
Network master/local
Head module
module
CH1
·
CHn
·
CH32
18.4 Writing Data to the Intelligent Device Station/Remote Device Station (32-bit Address Specified)
Intelligent function module
(s4)
(n)
word(s)
18 CC-LINK IE FIELD NETWORK INSTRUCTIONS
18
1617

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents