Mitsubishi Electric MELSEC iQ-R Series Programming Manual page 1911

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

■Operation result
1.
Function without EN/ENO
The operation processing is performed. The operation result is output from (d).
2.
Function with EN/ENO
The execution conditions and operation results will be as follows.
Execution condition
EN
TRUE (executed)
FALSE (not executed)
*1 If the value FALSE is output from ENO, the output data from (d) will be undefined. Create a program so that the undefined value will not
be used in operations.
If the operation result is outside the data type range, convert the input value as appropriate before operation.
Operation error
• When (s1) to (s28) are of REAL data type
Error code
Description
(SD0)
The value input to (s1) to (s28) is -0, a subnormal number, NaN (not a number), or .
3402H
3403H
The data output from (d) exceeds the following range. (An overflow has occurred.)
128
|(d)|<2
• When (s1) to (s28) are of LREAL data type
Error code
Description
(SD0)
The value input to (s1) to (s28) is -0, a subnormal number, NaN (not a number), or .
3402H
3403H
The data output from (d) exceeds the following range. (An overflow has occurred.)
1024
|(d)|<2
Operation result
ENO
TRUE
*1
FALSE
(d)
Operation result output value
Undefined value
27 ARITHMETIC OPERATION FUNCTIONS
27.2 Multiplication
27
1909

Hide quick links:

Advertisement

Table of Contents
loading