■TOD(P)
• These instructions write the n points of data from the device specified by (s2) to the buffer memory address specified by
(s1) and later in the buffer memory in the module or host CPU module specified by (U/H).
• Writing word data to a module
CPU module
(s2)
• Writing word data to the host CPU module
Device/label memory
(s2)
• If a constant is specified in (s2), the instructions write the same data (the value in the device specified by (s2)) to the (n)
words from the specified buffer memory address.
• Writing word data to a module
CPU module
(s2)
5
• Writing word data to the host CPU module
Device/label memory
(s2)
70000
• An instruction which has been executed will result in non-processing if it fails to access the target module because the
module is faulty or busy in processing.
7 APPLICATION INSTRUCTIONS
1060
7.27 Module Access Instructions
Buffer memory
(s1)
(n) points
CPU buffer memory of
the host CPU module (U/H)
(s1)
(n) points
Buffer memory
0
(s1)
CPU buffer memory of
the host CPU module (U/H)
(s1)
(n) words
(n) words
5
5
(n) words (The same data are written.)
5
70000
70000
(n) × 2 words (The same data are written.)
70000