Processing details
• These instructions switch the block number of the file register used in the program to that stored in the device specified by
(s). After the block number is changed, all file registers processed by the sequence program are those linked to the new
block number.
R0
Block No.0
(Currently being
used.)
R32767
Precautions
For the restrictions of the file register, refer to the following.
Page 65 Restrictions on using file registers
Operation error
Error code
Description
(SD0)
2820H
The specified file register does not exist.
3405H
The block number in the device specified by (s) does not exist.
7 APPLICATION INSTRUCTIONS
992
7.22 File Register Operation Instructions
Execution of the instruction
R0
Block No.1
(Used after the
execution of the
RSET instruction.)
R32767
(s)
Block number setting
R0
Block No.'n'
R32767