Pce-Controlled Lsp Protection; Pce-Controlled Lsp Ero - Juniper ACX1000 Configuration Manual

Junos os; acx series universal access router
Hide thumbs Also See for ACX1000:
Table of Contents

Advertisement

Copyright © 2017, Juniper Networks, Inc.
Table 47: Applicability of MPLS and Existing LSP Configurations to a
PCE-Controlled LSP
Support for PCE-Controlled LSP
These configuration statements can be
configured along with the PCE configuration.
However, they take effect only when the local
configuration is in use. During PCE control, these
configuration statements remain inactive.
These configuration statements can be
configured along with the PCE configuration,
but are overridden by the PCE-controlled LSP
attributes. However, when the local
configuration is in use, the configured values for
these configuration statements are applied.
NOTE:
Changes to the local configuration using
the CLI while the LSP is under the control of a
stateful PCE do not have any effect on the LSP.
These changes come into effect only when the
local configuration is applied.
These configuration statements cannot be
configured along with the PCE configuration.
The rest of the LSP configuration statements are applicable in the same way as for
existing LSPs. On configuring any of the above configuration statements for a
PCE-controlled LSP, an MPLS log message is generated to indicate when the configured
parameters take effect.

PCE-Controlled LSP Protection

The protection paths, including fast reroute and bypass LSPs, are locally computed by
the PCC using constraint-based routing. A stateful PCE specifies the primary path (ERO)
only. A PCE can also trigger a non-standby secondary path, even if the local configuration
does not have a non-standby secondary path for LSP protection.

PCE-Controlled LSP ERO

For PCE-controlled LSPs (PCC-delegated LSPs and PCE-initated LSPs), only a full-blown
Explicit Route Object (ERO) object has to be sent from the PCE to the PCC; otherwise
the PCC rejects the PCUpdate or PCCreate message for that PCEP session.
Starting in Junos OS Release 17.2, in addition to
types are introduced for the PCE-controlled LSPs:
—A PCC uses the
local cspf
Juniper Vendor TLV (enterprise number: 0x0a4c) of type 5.
Chapter 23: Configuring Path Computation Element Protocol (PCEP)
Applicable LSP
Configuration
Statements
admin-group
auto-bandwidth
hop-limit
least-fill
most-fill
random
bandwidth
primary
priority
p2mp
template
external cspf
local cspf
computation type only when the PCE sends in a
local cspf
Applicable MPLS
Configuration
Statements
admin-group
admin-groups
admin-group-extended
hop-limit
no-cspf
smart-optimize-timer
priority
p2mp-lsp-next-hop
, two new path computation
and
.
no cspf
703

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acx5048Acx5096Acx500Acx1100Acx2000Acx2100 ... Show all

Table of Contents