ACX Series Universal Access Router Configuration Guide
Purpose
Action
Meaning
716
Verification
Confirm that the configuration is working properly.
Verifying the PCEP Session Status on page 716
Verifying the PCE-Controlled LSP Status When LSP Control Is External on page 717
Verifying the PCE-Controlled LSP Status When LSP Control Is Local on page 718
Verifying the PCEP Session Status
Verify the PCEP session status between the PCE and Router PCC when the PCE status
is up.
From operational mode, run the
user@PCC>
show path-computation-client active-pce
PCE pce1
General
IP address
Priority
PCE status
Session type
PCE-mastership
Counters
PCReqs
PCReps
PCRpts
PCUpdates
Timers
Local
Keepalive timer:
Remote
Keepalive timer:
Errors
PCErr-recv
PCErr-sent
PCE-PCC-NTFS
PCC-PCE-NTFS
The output displays information about the current active stateful PCE that Router PCC
is connected to. The
PCE status
session between the PCE and Router PCC.
For
pce1
, the status of the PCEP session is
session has been established between the PCEP peers.
show path-computation-client active-pce
: 10.209.57.166
: 0
: PCE_STATE_UP
: PCE_TYPE_STATEFULACTIVE
: main
Total: 0
last 5min: 0
Total: 0
last 5min: 0
Total: 5
last 5min: 5
Total: 1
last 5min: 1
30 [s]
30 [s]
output field indicates the current status of the PCEP
PCE_STATE_UP
command.
last hour: 0
last hour: 0
last hour: 5
last hour: 1
Dead timer:
120 [s]
Dead timer:
120 [s]
, which indicates that the PCEP