3.2

Technical data of control electronics

Control terminal X210A
X210A.1
DC 20 V output (I
X210A.2
Ground 20 V/ Ground 24 V (ext.)
X210A.3
Digital input Controller Release
X210A.4
Digital inputs
X210A.5
X210A.6
X210A.7
Relay output X10
S3OUT.1 Monitoring function (factory setting)
1)
The control terminals are freely configurable.
Note:
The various configurations set the control terminals to defined adjustments. These adjustments can
be adapted to user-specific applications and various functions can be assigned to the freely pro-
grammable control terminals.
Digital inputs (X210A.3...X210B.1): Low Signal: DC 0...3 V, High Signal: DC 12...30 V,
Input resistance: 2.3 kΩ, response time: 16 ms, PLC compatible
X210A.6 and X210A.7 additional: frequency signal: DC 0 V...30 V, 10 mA at DC 24 V, f
Digital output (X210B.3): Low Signal: DC 0...3 V, High Signal: DC 12...30 V,
maximum output current: 40 mA, PLC compatible
Multi-function output (X210B.4):
analog signal: DC 24 V, maximum output current: 40 mA, pulse-width modulated (f
digital signal: Low Signal: DC 0...3 V, High Signal: DC 12...30 V, output current: 40 mA, PLC compati-
ble,
frequency signal: output voltage: DC 0...24 V, maximum output current: 40 mA,
maximum output frequency: 150 kHz
Multi-function input (X210B.6):
analog signal: input voltage: DC 0... 10 V (R
digital signal: Low Signal: DC 0...3 V, High Signal: DC 12 V...30 V, response time: 16 ms, PLC com-
patible
Conductor cross section:
The terminals are suitable for the conductor cross sections:
with wire end ferrule:
without wire end ferrule:
06/07
06/07
=180 mA)
max
1)
Technical data of the control terminals
=70 kΩ), input current: DC 0...20 mA (R
i
0.25...1.0 mm²
0.14...1.5 mm²
Operating Instructions ACTIVE
Operating Instructions ACTIVE
Control terminal X210B
X210B.1
Digital input
X210B.2
GND
X210B.3
Digital output
X210B.4
Multi-function output
signal proportional actual frequency
value, factory setting)
X210B.5
Supply voltage DC 10 V for refer-
ence value potentiometer,
(I
=4 mA)
max
X210B.6
Multi-function input
speed 0 ... +10 V, factory setting)
X210B.7
Ground 10 V
1)
1)
1)
(voltage
1)
(Reference
=150 kHz
max
= 116 Hz),
PWM
=500 Ω),
i
17