Detailed parameter 2

[Pr.25] Acceleration time 1 to [Pr.27] Acceleration time 3
Set the time for the speed to increase from 0 to [Pr.8] Speed limit value (to [Pr.31] JOG speed limit value during a JOG
operation control) during positioning. The specifications of this area are the same as those of [Pr.9] Acceleration time 0. For
details, refer to the following.
Page 382 [Pr.9] Acceleration time 0, [Pr.10] Deceleration time 0
■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
[Pr.25] Acceleration time 1
[Pr.26] Acceleration time 2
[Pr.27] Acceleration time 3
■Setting range
The setting range is 1 to 8388608.
■Default value
The default value is 1000 for all the axes.
[Pr.28] Deceleration time 1 to [Pr.30] Deceleration time 3
Set the time for the speed to decrease from [Pr.8] Speed limit value (from [Pr.31] JOG speed limit value during a JOG
operation control) to zero during positioning. The specifications of this area are the same as those of [Pr.10] Deceleration time
0. For details, refer to the following.
Page 382 [Pr.9] Acceleration time 0, [Pr.10] Deceleration time 0
■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
[Pr.28] Deceleration time 1
[Pr.29] Deceleration time 2
[Pr.30] Deceleration time 3
■Setting range
The setting range is 1 to 8388608.
■Default value
The default value is 1000 for all the axes.
Axis 1
36
37
38
39
40
41
Axis 1
42
43
44
45
46
47
17 DATA USED FOR POSITIONING CONTROL
Axis 2
186
187
188
189
190
191
Axis 2
192
193
194
195
196
197
17.3 Basic Setting
17
391