[Cd.35] Step valid flag
Set whether to validate step operations.
Step valid flag
Do not carry out step operation
Carry out step operation
■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
[Cd.35] Step valid flag
■Default value
The default value is 0: Do not carry out step operation for all the axes.
[Cd.36] Step start request
When the step function is used, set this area to continue the operation stooped by the step operation.
• The step operation continues by setting 1: Continue step operation for this area of the axis where step operation is stopped
correctly.
• After the step start request is accepted, 0 is automatically stored. Storing 0 indicates the completion of the step start
request acceptance.
■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
[Cd.36] Step start request
■Default value
The default value is 0 for all the axes.
[Cd.37] Skip command
Set this area to skip the current positioning operation.
• The current positioning operation is skipped and the next positioning starts by setting 1: Issue a skip command to execute
the machine deceleration, stop, and start the next positioning operation for this area.
• After the skip request is accepted, 0 is automatically stored. Storing 0 indicates the completion of the skip request.
■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
[Cd.37] Skip command
■Default value
The default value is 0 for all the axes.
Setting value
0
1
Axis 1
1545
Axis 1
1546
Axis 1
1547
17 DATA USED FOR POSITIONING CONTROL
Axis 2
1645
Axis 2
1646
Axis 2
1647
17.8 Control Data
17
467