Example 3
When JOG start signal is turned on again during the deceleration due to turning off of JOG start signal, the JOG operation is
performed from the point when JOG start signal is turned on.
[Cd.181] Forward JOG
start signal
[Md.141] BUSY signal
Example 4
If JOG start signal is turned on while using GX Works3 test mode, JOG start signal is ignored and the JOG operation is not
performed.
[Md.1] In test mode
Flag
[Cd.181] Forward JOG
start signal
11 MANUAL CONTROL
194
11.2 JOG Operation
ON
OFF
ON
OFF
JOG operation is not possible
because the JOG start signal
JOG operation is
was already on at this timing
not possible while
(operation starts at the next
the test function
rising of the JOG start signal)
is in use
ON
ON
OFF
Forward JOG operation
OFF
t
Forward JOG
operation execution
t