[Pr.51] OPR acceleration time selection
Set which of Acceleration time 0 to 3 to use for the acceleration time during OPR.
OPR acceleration time
selection
Acceleration time 0
Acceleration time 1
Acceleration time 2
Acceleration time 3
■Buffer memory address
The following table shows the buffer memory address of this area.
Name
[Pr.51] OPR acceleration time selection
■Default value
The default value is 0: Acceleration time 0 for all the axes.
[Pr.52] OPR deceleration time selection
Set which of Deceleration time 0 to 3 to use for the deceleration time during OPR.
OPR deceleration time
selection
Deceleration time 0
Deceleration time 1
Deceleration time 2
Deceleration time 3
■Buffer memory address
The following table shows the buffer memory address of this area.
Name
[Pr.52] OPR deceleration time selection
■Default value
The default value is 0: Acceleration time 0 for all the axes.
17 DATA USED FOR POSITIONING CONTROL
406
17.3 Basic Setting
Setting
Description
value
0
Uses the value set in [Pr.9] Acceleration time 0.
1
Uses the value set in [Pr.25] Acceleration time 1.
2
Uses the value set in [Pr.26] Acceleration time 2.
3
Uses the value set in [Pr.27] Acceleration time 3.
Axis 1
82
Setting
Description
value
0
Uses the value set in [Pr.10] Deceleration time 0.
1
Uses the value set in [Pr.28] Deceleration time 1.
2
Uses the value set in [Pr.29] Deceleration time 2.
3
Uses the value set in [Pr.30] Deceleration time 3.
Axis 1
83
Axis 2
232
Axis 2
233