Mitsubishi Electric MELSEC iQ-F Series FX5 User Manual page 152

Positioning control - intelligent function module
Hide thumbs Also See for MELSEC iQ-F Series FX5:
Table of Contents

Advertisement

Position-speed switching signal setting
■When External command signal (CHG) is used
To use External command signal (CHG) as Position-speed switching signal, set the following items.
Setting item
[Pr.42]
External command function
selection
[Cd.8]
External command valid
[Cd.45]
Speed-position switching
device selection
■When Near-point dog signal (DOG) is used
To use Near-point dog signal (DOG) as Position-speed switching signal, set the following items.
Setting item
[Cd.45]
Speed-position switching
device selection
[Pr.42] External command function selection and [Cd.8] External command valid are not required to be set.
■When [Cd.46] Speed-position switching command is used
To use [Cd.46] Speed-position switching command as Position-speed switching signal, set the following items.
Setting item
[Cd.45]
Speed-position switching
device selection
[Pr.42] External command function selection and [Cd.8] External command valid are not required to be set.
9 MAJOR POSITIONING CONTROL
150
9.2 Positioning Data Settings
Setting
Setting details
value
2
Set "2: Speed-position/position-speed switching
request".
1
Set "1: Enable external commands".
0
Set "0: Use external command signals".
Setting
Setting details
value
1
Set "1: Use near-point dog signals".
Setting
Setting details
value
2
Set "2: Use [Cd.46] Speed-position switching
command".
Buffer memory address
Axis 1
Axis 2
62
212
1505
1605
1566
1666
Buffer memory address
Axis 1
Axis 2
1566
1666
Buffer memory address
Axis 1
Axis 2
1566
1666

Advertisement