Block start data

Set the block start data number 0 to 4 for each axis.
Item
Shape
Start data No.
Special start instruction
Parameter
Condition data
Set condition data for each block start data.
■Setting method
Setting range
• 0: Termination
• 1: Continue
1 to 600
• 00H: Normal start
• 01H: Condition start
• 02H: Wait start
• 03H: Simultaneous start
• 04H: FOR loop
• 05H: FOR condition
• 06H: NEXT start
• 1 to 10
• 0 to 255
1.
2.
3.
4.
5.
6.
Reference
Page 422 [Da.11] Shape
Page 423 [Da.12] Start data No.
Page 423 [Da.13] Special start instruction
Page 424 [Da.14] Parameter
Double-click "Condition data edit" in "Axis  Block start
data".
Click the cell of the condition data number to be edited
and click the [Edit] button.
Select settings of "Condition Operator" and "Condition
Identifier" from the pull-down menu.
Set "Condition Data" according to the condition set in
step 3.
Click the [OK] button.
Click the [Close] button.
14 PARAMETER SETTING
14.3 Module Extension Parameter