Mitsubishi Electric MELSEC iQ-F Series FX5 User Manual page 404

Positioning control - intelligent function module
Hide thumbs Also See for MELSEC iQ-F Series FX5:
Table of Contents

Advertisement

[Pr.45] OP address
Set the address used as the reference point for positioning control (ABS system).
(When the machine OPR is completed, the stop position address is changed to the address set in [Pr.45] OP address. At the
same time, the value set in [Pr.45] OP address is stored in [Md.20] Current feed value and [Md.21] Machine feed value.)
■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
[Pr.45] OP address
■Setting range
The setting range depends on the setting of [Pr.1] Unit setting.
Setting of [Pr.1] Unit setting
0: mm
1: inch
2: degree
3: pulse
*1 When this buffer memory area is set with programs, a calculation is performed in the positioning module to convert a setting value to the
value in each unit. For setting this buffer memory area, take the value after the unit conversion into consideration.
■Default value
The default value is 0 for all the axes.
[Pr.46] OPR speed
Set the speed for OPR.
Set OPR speed to a value equal to or less than the value set in [Pr.8] Speed limit value. If the value exceeds the value set in
Speed limit value, OPR speed error (Error code: 1B04H) occurs and the OPR is not performed.
Set OPR speed to a value equal to or more than the values set in [Pr.7] Bias speed at start and [Pr.47] Creep speed.
■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
[Pr.46] OPR speed
■Setting range
The setting range depends on the setting of [Pr.1] Unit setting.
Setting of [Pr.1] Unit setting
0: mm
1: inch
2: degree
3: pulse
*1 When this buffer memory area is set with programs, a calculation is performed in the positioning module to convert a setting value to the
value in each unit. For setting this buffer memory area, take the value after the unit conversion into consideration.
■Default value
The default value is 1 for all the axes.
17 DATA USED FOR POSITIONING CONTROL
402
17.3 Basic Setting
Axis 1
72
73
Setting value via GX Works3
-214748364.8 to 214748364.7 (μm)
-21474.83648 to 21474.83647 (inch)
0 to 359.99999 (degree)
-2147483648 to 2147483647 (pulse)
Axis 1
74
75
Setting value via GX Works3
0.01 to 20000000.00 (mm/min)
0.001 to 2000000.000 (inch/min)
0.001 to 3000000.000 (degree/min)
1 to 5000000 (pulse/s)
Axis 2
222
223
Setting value with programs
-2147483648 to 2147483647 (×10
-2147483648 to 2147483647 (×10
-5
0 to 35999999 (×10
degree)
-2147483648 to 2147483647 (pulse)
Axis 2
224
225
Setting value with programs
-2
1 to 2000000000 (×10
mm/min)
-3
1 to 2000000000 (×10
inch/min)
-3
1 to 3000000000 (×10
degree/min)
1 to 5000000 (pulse/s)
*1
-1
μm)
-5
inch)
*1

Advertisement

Table of Contents
loading

Table of Contents