Speed change test
For the axes started with the positioning start test, OPR test, and JOG operation test, perform the speed change function,
acceleration/deceleration time change function, or override function to check the proper speed or acceleration/deceleration
time.
■Speed change
1.
Select a target axis to be tested from the pull-down menu of "Target Axis".
2.
Select "New Speed" from the pull-down menu of "Select Function".
3.
Set "New Speed Value".
4.
Click the [New Speed] button. The set value of "New Speed Value" is reflected to the positioning control being performed.
■Override function
1.
Select a target axis to be tested from the pull-down menu of "Target Axis".
2.
Select "New Speed" from the pull-down menu of "Select Function".
15 MONITORING/TEST
335
15.2 Positioning Test