When setting positioning data using a program, determine buffer memory addresses using the following calculation formula
and set the addresses.
• 2000+6000×(Ax-1)+10×(N-1)+S
For each variable, substitute a number following the description below.
Item
Ax
N
S
Ex.
When the buffer memory address of [Da.9] Dwell time of the positioning data No.200 of axis 2 is determined
2000+6000×(2-1)+10×(200-1)+2=9992
Description
The axis number of the buffer memory address to be determined. Substitute a number from 1 to 2.
The positioning data No. of the buffer memory address to be determined. Substitute a number from 1 to 600.
Substitute one of the following numbers according to the buffer memory address to be determined.
• Positioning identifier ([Da.1] to [Da.5]): 0
• [Da.10] M code: 1
• [Da.9] Dwell time: 2
• Positioning option ([Da.27] to [Da.29]): 3
• [Da.8] Command speed (lower 16 bits): 4
• [Da.8] Command speed (upper 16 bits): 5
• [Da.6] Positioning address/movement amount (lower 16 bits): 6
• [Da.6] Positioning address/movement amount (upper 16 bits): 7
• [Da.7] Arc address (lower 16 bits): 8
• [Da.7] Arc address (upper 16 bits): 9
Appendix 5 How to Find Buffer Memory Addresses
A
APPX
541