■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
[Pr.23] Output signal logic selection
■Default value
Each input signal of all the axes is set to 0: Negative logic.
[Pr.24] Manual pulse generator input selection
Set the input pulse mode from the manual pulse generator. (Only the setting value specified for the axis 1 is valid.)
Manual pulse generator input selection
A-phase/B-phase multiple of 4
A-phase/B-phase multiple of 2
A-phase/B-phase multiple of 1
PULSE/SIGN
■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
[Pr.24] Manual pulse generator input selection
■Default value
The default value is 0: A-phase/B-phase multiple of 4.
[Pr.150] Speed-position function selection
Select the mode of speed-position switching control.
Speed-position function selection
Speed-position switching control (INC mode)
Speed-position switching control (ABS mode)
If a value other than 0 and 2 is set, the control is performed in the INC mode with the setting value regarded as 0.
■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
[Pr.150] Speed-position function selection
■Default value
The default value is 0: Speed-position switching control (INC mode) for all the axes.
17 DATA USED FOR POSITIONING CONTROL
390
17.3 Basic Setting
Axis 1
32
Setting value
0
1
2
3
Axis 1
33
Setting value
0
2
Axis 1
34
Axis 2
182
Axis 2
Axis 2
184